22 results (0,14084 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vimpex SL-FXP-25 P Clip for Signaline LHD Cable Pack of 25

Vimpex DC-SAA-102-STD Door Coordinator - Standard Rebate - 102 mm Arm - Anodised Aluminium

C-Tec CP414T CAST-PRO Smoke Heat Multisensor cw Tone Sounder

RGL Electronics KP50 InternalExternal Keypad - Heavy Duty - Stainless Steel - Surface Mounted

Videx 521B Boxed 13.8B DC-13V AC amp Battery Back-up Power Supply Unit

RGL Electronics RD26-C InternalExternal Surface Mounted Wiegand Reader

C-Tec CP411 CAST-PRO CO Fire Smoke Heat Multisensor

RGL Electronics CP12-8 12VDC Power Supply With Indicator - 8x Output Fuses

RGL Electronics CP12-10 12VDC Power Supply With Indicator - 10x Output Fuses

RGL Electronics CP12-16 12VDC Power Supply With Indicator - 16x Output Fuses

RGL Electronics CP12-5 12VDC Power Supply With Indicator - 5x Output Fuses

Aritech DC109 Extra Heavy Duty Surface Industrial OverheadFloor Mount Contact

C-Tec CA457AW CA C Class Base Voice Sounder VAD - White

Zeta ZRPBW Conventional Raptor Sounder Beacon White Plastic White Flash

C-Tec BF330CTSR 24V Loop Sounder - Shallow Base - Red

ACT 1336 Digital Light Level Meter

C-Tec BF333CTDR 24V Loop Sounder VID Deep Base - Red

Fireclass 577.001.036FC 602SB Conventional 2 Wire Sounder Base

C-Tec CA455AW CA O Class Base Voice Sounder VAD White

System Sensor M200XE Loop Isolation Module

System Sensor M200XE Loop Isolation Module

System Sensor M200XE Loop Isolation ModuleThere is a large number of System Sensor intelligent fire alarm systems the address loop with a recipient device up to 198 is protected by a single one loop interruption but in the case of loop short circuit the entire loop it may become inoperable. With the M200XE modules shorting is not desired can be reduced.Only a small part of the system falls out if the loop is broken down into isolators because in the case of a possible loop only the two isolators will not be available to the control panel. If the address loop voltage drops below 7V the isolator module - with FET on the branch breaks it off the loop in the non-short-term part of the address loop the assets remain operational. If the breakdown the loop voltage rises on one side of the module then the separated short-circuit loop section 3 mA max. 15 mA control current flows through the module.In isolation the address loop wires between min. 2.2 kOhm resistance. The isolated state is maintained until the voltage of the disconnected section is 7V the short-circuit or the abnormally high current consumption ceases to exist. After the termination of the termination the isolator disengages the loop automatically.The two-colour LED on the module flashes green in the normal state of the loop every 3 seconds. If the module on any side it detects a short-circuit it illuminates with continuous yellow light during the shutter. The M200XE module in the M200E-SMB mounting box is wall-mounted with the M200E-DIN clip directly on the DIN rail M200E-PMB clip can be mounted in the fire panels box.

GBP 55.08
1

C-Tec Addressable Compact C-3-8 Ceiling VAD cw 90dBA Sounder - BF451ACXSW

C-Tec Addressable Compact C-3-8 Ceiling VAD cw 90dBA Sounder - BF451ACXSW

C-Tec Addressable Compact C-3-8 Ceiling VAD cw 90dBA Sounder - BF451ACXSWBF451ACXSW Compact Addressable Ceiling VAD cw 90dBA Sounder utilises the latest advances in sounder LED and LED lens technology to provide a truly exceptional C-3-8 fire alarm warning device.Compatible with C-TECs ZFP XFP range of Apollo XP95Discovery addressable fire panels its 550A quiescent current and low 14mA alarm current VAD lit sounder on max make it one of the most efficient EN54-323 compliant sounderVADs on the market.Other features include seven selectable volume levels15 tone pairs a flash rate of 0.5Hz once every two seconds and a group addressing function to ensure the synchronised operation of multiple devices.Attractively finished in white polycarbonate the BF451ACXSW comes with an integrated sounder VADbase locking mechanism and a plastic ID tag.The BF451ACXSW can also be used to provide W-2.4-3.5 coverage when mounted on a wall.Key FeaturesThird-party certified to EN54-3 Sounders EN54-23 VADs and 17 Isolators by Intertek pendingProvides C-3-8 light distribution when ceiling mounted min 0.4 lux over a 3 x 8m cylindrical areaCan also provide W-2.4-3.5 light distribution when wall mounted min. 0.4 lux over a 2.4 x 3.5m cuboid areaImpressive 90dBA sound output 1mUnique C-TEC designed lens maximises light output whilst minimising current drawOnboard short-circuit loop isolator550uA quiescent current14mA alarm current 24V DC VAD lit sounder on maxAttractively finished in white polycarbonate light output is whiteGroup addressing facility allows multiple devices to be operated simultaneously7 selectable volume levels and up to 15 selectable tone pairsAttractive compact design - just 102mm diameter 63mm deepIncludes an integrated sounder to base locking mechanismIP21C ratedLow current consumption means multiple devices can be connected to the loopDIP switch addressedSimple click and twist design and easy-fit base ensures rapid installation timeAlso available in a red plastic housing order code BF451ACXSR

GBP 47.84
1