Kidde Airsense EST-VES-4001-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-L PAVA EST Voice Evacuation System 4xAB 8 lines amp 2x320W inc. spare amp. 1xaudio LCD fireman mic charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charged with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStandalone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 3359.02
1

Kidde Airsense EST-VES-4001-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-LN PAVA EST Voice Evacuation System4xAB 8 lines amp 2x320W inc. spare amp. 1xaudio LCD fibre network card fireman mic. charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charger with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStand alone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 4043.26
1

Kidde Airsense EST-VES-4002-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-LN PAVA EST Voice Evacuation System4xAB indep. 8 lines amp. 2x320W inc. spare amp. 2xaudio LCDfiber network card fireman mic. charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charger with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStand alone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 4306.37
1

Kidde Airsense EST-VES-4002-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-L PAVA EST Voice Evacuation System4xAB indep. 8 lines amp. 2x320W inc. spare amp. 2xaudio LCD fireman mic. charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charger with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStand alone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 3402.77
1

Kidde NC-MCS99-0-W White Intelligent Conventional Recess Mount Manual Call Point Abort Extinguishing System Text

Kidde NC-MCS99-0-W White Intelligent Conventional Recess Mount Manual Call Point Abort Extinguishing System Text

Kidde NC-MCS99-0-W White Intelligent Conventional Recess Mount Manual Call Point Abort Extinguishing System TextThe NC-MCS99-0-W is a yellow manual call point for recess mount applications on most industry standard high quality wall boxes. For surface mount applications an optional colour matched back box is available.The call point offers one normally open contact in series with a 0 resistor as well as a single pole changeover contact with common normally open and normally closed connections. It is supplied with a EN54 style resettable element pluggable connectors for both contacts a handy wire bridge to help with cable continuity testing as well as test key that doubles up as a service tool for disassembly of the device.Key FeaturesSpecifically designed for extinguishing control systemsAlarm indication by alarm flagEnhanced aesthetics with screen printed high resolution functional markingResettable and also usable with an optional frangible elementEasy to install plug and playVarious surface and recess mounting options available for installation flexibilityProtection hinged cover with anti-tamper facilities available for avoiding accidental activationBackward compatible adapter available for retrofit applications in existing systemsKey test facility from the front of the unit for easy access even when a protection cover is fittedEasy service and maintenance with test key disassembly and pluggable connectors

GBP 18.20
1

Kidde NC-MCS99-0-Y Yellow Intelligent Conventional Recess Mount Manual Call Point Manual Release Extinguishing System Text

Kidde NC-MCS99-0-Y Yellow Intelligent Conventional Recess Mount Manual Call Point Manual Release Extinguishing System Text

Kidde NC-MCS99-0-Y Yellow Intelligent Conventional Recess Mount Manual Call Point Manual Release Extinguishing System TextThe NC-MCS99-0-Y is a yellow manual call point for recess mount applications on most industry standard high quality wall boxes. For surface mount applications an optional colour matched back box is available.The call point offers one normally open contact in series with a 0 resistor as well as a single pole changeover contact with common normally open and normally closed connections. It is supplied with a EN54 style resettable element pluggable connectors for both contacts a handy wire bridge to help with cable continuity testing as well as test key that doubles up as a service tool for disassembly of the device.Key FeaturesSpecifically designed for extinguishing control systemsAlarm indication by alarm flagEnhanced aesthetics with screen printed high resolution functional markingResettable and also usable with an optional frangible elementEasy to install plug and playVarious surface and recess mounting options available for installation flexibilityProtection hinged cover with anti-tamper facilities available for avoiding accidental activationBackward compatible adapter available for retrofit applications in existing systemsKey test facility from the front of the unit for easy access even when a protection cover is fittedEasy service and maintenance with test key disassembly and pluggable connectors

GBP 18.20
1

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit.EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems.It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity. In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers. If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier.The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system. Furthermore EST-CU-11LT can be equipped with an LCD touch screen with a control module which allows easy access to management functions and monitoring of the whole system such extended configuration is included in EST-CU-11LCD Control Unit.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 2213.64
1

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 x 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit. EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems. It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity.In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers.If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier. The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 1823.00
1

Kidde Airsense EST-XAUDIO-48-RS Function Card 4 IN 8 OUT Audio RS485

Kidde Airsense Stratos-HSSD 2 - Minimum Display Version 9-30710

Kidde Airsense Command Module Without Stratos-HSSD 2

Kidde Airsense Stratos-HSSD 2 Standard Detector 9-30621

Kidde Airsense EST-PSM48 Power Supply Manager

Carrier KP2000 Keypad FPFR12002000

Kidde Airsense EST-PS48800 Power Supply

Kidde Airsense EST-PS48800 Power Supply

Kidde Airsense EST-PS48800 Power SupplyEST-PSM48 Power Supply Manager is designed for distribution of DC Power Supply from Power Supply Units PSU and a back-up battery. The unit controls battery charging and distributes power supply to all Voice Evacuation System VES equipment at max 60 A. When the system uses battery back-up the power supplied is 3.2 kW 48 V.The unit complies with the EN 54-4 VES standards and also EN 12101-10 Smoke and Heat Control System standards. As a main source of energy distribution the manager uses external modules 800 W EST-PS48800 for 48 V.As a source of stand-by power supply it uses the battery bank of the capacity of up to 200 Ah.EST-PSM48 cooperates with the 4 x 12 V VRLA battery bank. It maintains the bank in charged condition ensures temperature compensation of charging parameters and monitors serial resistance of the battery and its wiring as specified in Exhibit No. A2 to the EN54-4 Standard.EST-PSM48 co-operates with up to 4 modules of EST-PS4880 Power Supply Units. The manager ensures safe connection for the purpose of parallel operations and monitors the output parameters of each power supply unit.EST-PS48800 is designed for assembling in a dedicated EST-PF4 Power Supply Unit Frame. The elements of the system are designed for assembling in a Rack 19 IP30-type.Key FeaturesPower consumption 885 W max. 3.85 AAC power supply 230 VAC 10 -15 5060Hz 3.85 A Wire with IEC 60320 C13 3x075 mm2 coupling supplied with the unitCertification EN54-4Standards EN12101-10

GBP 697.18
1

Kidde Airsense Stratos-HSSD 2 Detector Fitted With Command Module 9-30620

Kidde 1X-X3E-99 Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Eng Int

Kidde 1X-X3E-99 Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Eng Int

Kidde 1X-X3E-99 Conventional Fire Extinguishing Panel With UI - 3 Zone - Full Opt Eng IntThe 1X-X3E-99 is a networkable enhanced conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The 1X fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any dcor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking black lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs. The 1X-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organization and planning.Key FeaturesSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportIntrinsically safe and EN54-13 zone support

GBP 412.79
1

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function Slots

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function Slots

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function SlotsESTCU-8LCD Control Unit CU is a matrix mixer of input signals which routes to 4 x 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit.In basic factory configuration EST-CU-8LCD is a stand-alone system which enables only connections with DFMS and zone microphones.For networking with other CU optional xNet card is needed.The CU is equipped with 1x EST-xCtrLine-4 card in slot 1 1x ESTAudIO-48-RS card in slot A and 1x EST-LogIN-8f card in slot B. Slot C and D can extend control unit audio dsp abilities up to 24 audio outputs 12 audio inputs. Slots from 2 to 7 are free for any cards assignment EST-xCtrLine-24 and EST-xLogINOUT.Furthermore EST-CU-8LCD is equipped with an LCD touch screen with a control module which allows easy access to management functions and monitoring of the whole system.Key Features Network-based system allowing configuration diagnostics and management via EthernetManaging up to 254 devices on the network7 slots available for any configuration of loudspeaker control cards control input and output cardsAdditional 2 slots designated for audio inputoutput cards and control input output cardsUp to 8 messages played simultaneously in different zonesUp to 32GB SD flash memory designated for playback and recording messages 48 kHz 16 bitSupport of up to 12 secured amplifiersOptional equipment EST-xNET-1GbWANRS for optical fibre redundant connectionIntegrated DSP with implemented 3 band parametric EQ on all inputs on control units 8 band parametric EQ delay lines audio limiter and feedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enabling seamless integration of the EST ENT VES system with 3rd party systems thanks to implementation of standard and proprietary communication interfaces

GBP 1953.20
1

Kidde Airsense Stratos Sampling Hole Warning Labels 9-10960

Kidde 1-23911-K070 Firebeta XT Ancillary PCB

Kidde 1-23911-K070 Firebeta XT Ancillary PCB

Kidde 1-23911-K070 Firebeta XT Ancillary PCBThe Kidde 1-23911-K070 FireBeta XT Ancillary PCB is an accessory to the EN approved FireBeta XTXT extinguishing control panels. These ancillary boards extend the signals from the extinguishing system to other control or signalling equipment e.g. the building management BMS or other fire alarm systems that may be present in the building.Up to 7 ancillary boards can be connected to the FireBeta XTXT control panel via a fully monitored RS485 communication link. This allows for the same signalling capabilities at multiple locations up to 1200 m away from the main control panel.Every ancillary board is provided with 10 potential free changeover contact outputs each allocated to a specific extinguishing system function. On board status LEDs are provided to indicate the status of each output. These LEDs illuminate when the output is active.Ancillary boards may be mounted inside the extinguishing control panel cabinet or remotely in external enclosures. Every ancillary board is given a unique address to enable accurate location reporting of communication faults between the panel and the board.Supported Output FunctionsThe following area status can be signalledZone 1 fireZone 2 fireZone 3 fireManual only mode activatedDisablement activeGas release confirmationExtinguishing release countdown activatedManual release operatedExtract fan output operatedHold circuit activatedKey FeaturesPotential free contacts for remote signalling of extinguishing system statusSupervised 2-wire RS485 data connectionUp to 7 boards per systemLED indicators confirm relay operationMay be mounted inside the extinguishing panel cabinet or remotely

GBP 195.72
1

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725

Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725The AirSense Micra 10 is designed to provide very high sensitivity smoke detection in a small package. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area.The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems.ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesUltra-small low-cost aspirating smoke detector for easy and discreet installationHigh sensitivity provided by laser based forward light scatter for reliable early warningSingle sampling pipe up to 50m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination system

GBP 888.07
1

Kidde Airsense Stratos 27mm 90 Degree Bend 9-10906

Kidde Airsense Stratos 27mm Plain Socket 9-10908

Kidde Airsense Stratos 27mm T Piece Pipework 9-10909