8 results (0,12827 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde Airsense ADELCU-EOL Spare End-of-Line Unit

Kidde Airsense EST-T1510 Fire Horn Speaker - Power 10W 100V

Kidde Airsense EST-T1510 Fire Horn Speaker - Power 10W 100V

Kidde Airsense EST-T1510 Fire Horn Speaker - Power 10W 100VEST-T1510 is a Fire Horn Speaker designed for both indoor and outdoor operation.Horn-type fire alarm EST-T loudspeakers are designed for either simple or most complex and sophisticated sound-transmitting applications. They combine excellent acoustic parameters and high aesthetics with resistance to mechanical damages and varying weather conditions as well as simple assembling and low price. Quality standards and audio characteristics have been confirmed through tests and trials employing echo-proof chamber resistance and integrity testing equipment as well as chambers for resistance to weather and air humidity testing.The EST-T series comprises highly efficient loudspeakers which produce sounds featuring directional characteristics and operate in any atmospheric conditions A B C environmental type. Thanks to their balanced frequency band they guarantee high understanding of verbal communication. Furthermore they can transmit musical background.Their casings are made of ABS UL94V0 a synthetic material featuring high resistance to mechanical damages and self-extinguishing properties. Loudspeakers are perfectly protected from dust and humidity IP66. The assembling jig ensures adjusting the inclination for the optimum coverage of the area of communications.EST-T loudspeakers are applied on circulation routes and inside the rooms with high after-sound as well as in widespread outdoor area broadcasting. They are unparalleled on sport sites at swimming pools in expo and industrial halls warehouses open and underground car parks and in open areas such as e.g. stadiums parks etc.EST-T loudspeakers entirely comply with global requirements concerning evacuation systems including the standards such as BS5839 Part 8 and EN 54-24. They have been certified for product compliance and acceptance by ITB. Ceramic blocks internal flame-resistant wiring and temperature limit fuses protect the broadcasting line from short-circuits or breaks and ensure continuous operations even in case of fire-produced damages or burns. The loudspeaker located in the zone of fire is isolated from the sound-transmitting line.A special design eliminates the risk of fall of any of its burnt components which ensures safe fire escape process. This feature has been confirmed by means of the most rigorous testing under the temperature of 822C ambient temperature.Our EST-T loudspeaker offer comprises three power rating models i.e. 10 W 15 W and 30 W. The individual rated power is selected by means of connection with applicable transformer branch. All the EST-T loudspeakers are designed so as to ensure continuous operations at rated parameters for at least 100 hours consistent with IEC-268-5 Standard.In spite of the fact our loudspeakers are designed for the highest reliability under fire conditions they can be also used in any and all public address systems.Key Features10W 100V1.25 Width156mm DiameterIP rating IP66Colour Light Grey

GBP 63.55
1

Kidde Airsense EST-S136 Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 13 cm

Kidde Airsense EST-S136 Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 13 cm

Kidde Airsense EST-S136 Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 13 cmCeiling-mounted fire alarm loudspeakers EST-S106 and EST-S136 are designed for applications which require the minimum size at the maximum sound quality. Their parameters have been carefully selected to match the operating requirements in the rooms exposed to after-sound and high-humidity. Thanks to the most advanced technologies the EST-S series loudspeakers combine excellent acoustic parameters and high aesthetics with resistance to mechanical damages and varying weather conditions.They are distinguished by easy and quick installation. Quality standards and audio characteristics have been confirmed through multiple tests and trials employing such facilities as e.g. echo proof chamber resistance and integrity testing equipment as well as chambers for resistance to weather and air humidity testing. The need to maintain the best acoustic parameters even with easily installed fire-protecting screens was the idea underlying the design process.The EST-S series loudspeakers ensure a balanced sound which is extremely important in emission of highly understandable speech and reliable music reproduction. The series of ceiling-mounted EST-S loudspeakers is noticeable thanks to its elegant looks. The loudspeaker part which becomes visible after the installation is protected by means of electroplating and covered by a common and aesthetic white paint coat RAL 9003 optionally available other colours RAL palette.The entire EST-S series is equipped with a standardized fire dome made of soft steel and supplied with two cable penetrations with rubber glands. Special jig for sling assembling facilitates quick installation. The delivery comprises the 1 m long sling. Two ceramic blocks and fireproof wiring coupled with temperature limit fuse are located under the screen. This solution ensures 100 protection of the sound transmitting line from any break or short-circuits which may be produced as a result of loudspeaker burn. The EST-S loudspeakers have been successfully tested by means of the most rigorous trials at the temperature of 822C. The individual power rating is selected by means of connection with applicable transformer branch.EST-S series loudspeakers equipped with fire dome and thermal protections entirely comply with EN 54-24 Standards. In order to ensure 100 consistency with the highest quality standards we test our loudspeakers following the most meticulous procedures that warrant high parameters of sound emission safety and reliability. In spite of the fact our loudspeakers are designed for the highest reliability under fire conditions their acoustic parameters and attractive low prices make them successful in any and all public address systems.Key FeaturesCompliance with EN 54-24Certificate of Conformity 1438-CPR-XXXXMinimum dimensionsA and C working environment ideal for bathroomsThe highest level of verbal communication understandingElegant looks6 W transformer allowing a precise selection of loudspeaker output power100 protection of line from breaks and short-circuits at the temperature of 822C

GBP 46.09
1

Kidde Airsense Stratos-Micra 100 9-30672

Kidde Airsense Stratos-Micra 100 9-30672

Stratos-Micra 1009-30672Stratos-Micra 100 has two pipe inlets and supports a maximum of 100 metres of sampling pipe. Stratos-Micra will be available with an optional Piped Exhaust type Docking Station. This is primarily intended to allow the Stratos-Micra detector to sample from areas which may be at different air pressure to the detector location. Typical uses are for air-duct sampling and allowing the installation of the detector in under-floor or ceiling voids or when sampling from pieces of computer related equipment.Stratos-Micra will provide four alarm level outputs and a fault output to the fire alarm panel. Relays for Fire 1 and Fault are fitted as standard. When an addressable panel is used the Addressable Protocol Interface Card APIC is used to communicate using the addressable protocol. By using the APIC means that the alarm and fault relays can be used for other purposes.Stratos-Micra is supplied with comprehensive diagnostic facilities as standard. By simply plugging a PC into the serial port display diagnostic menus will give the capability of fault finding down to individual component level. ClassiFire-3D may be viewed working in real time. It is also possible to view a detailed chart recorder of historical smoke levels showing date time and alarm thresholds.Key FeaturesSmall low cost aspirating smoke detector for easy and discreet installationHigh sensitive provided by laser based forward light scatter for reliable early warningTwo sampling pipes 100m aggregate for flexibilityUnique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and the system contaminationUnwanted alarms from dust are avoided using patented dual technology LDD 3D laser dust discrimination and elimination system

GBP 1585.55
1

Kidde Airsense Stratos-Micra 100 Relay Input Card

Kidde Airsense Stratos-Micra 100 Relay Input Card

Stratos-Micra 100 Relay Input CardStratos-Micra 100 has two pipe inlets and supports a maximum of 100 metres of sampling pipe. Stratos-Micra will be available with an optional Piped Exhaust type Docking Station. This is primarily intended to allow the Stratos-Micra detector to sample from areas which may be at different air pressure to the detector location. Typical uses are for air-duct sampling and allowing the installation of the detector in under-floor or ceiling voids or when sampling from pieces of computer related equipment.Stratos-Micra will provide four alarm level outputs and a fault output to the fire alarm panel. Relays for Fire 1 and Fault are fitted as standard. When an addressable panel is used the Addressable Protocol Interface Card APIC is used to communicate using the addressable protocol. By using the APIC means that the alarm and fault relays can be used for other purposes.Stratos-Micra is supplied with comprehensive diagnostic facilities as standard. By simply plugging a PC into the serial port display diagnostic menus will give the capability of fault finding down to individual component level. ClassiFire-3D may be viewed working in real time. It is also possible to view a detailed chart recorder of historical smoke levels showing date time and alarm thresholds.Key FeaturesSmall low cost aspirating smoke detector for easy and discreet installationHigh sensitive provided by laser based forward light scatter for reliable early warningTwo sampling pipes 100m aggregate for flexibilityUnique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and the system contaminationUnwanted alarms from dust are avoided using patented dual technology LDD 3D laser dust discrimination and elimination system

GBP 1707.50
1

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control UnitThe ADELCU-2 digital location control unit is a dual zone module for monitoring up to two zones of AlarmLine II Digital EN Linear Heat Detection Cable. If an overheat or fire situation triggers either zone of the digital cable the unit automatically calculates and displays the distance along the cable in feet and metres to the alarm point.The two zones can operate independently of each other or in interlock mode. A separate alarm and normally conducting fault output are provided for each zone. The unit is intended to be installed between the AlarmLine II digital EN linear heat detection cable and a conventional or addressable fire alarm control panel. It has power fault and alarm indicators as well as free outputs for fault and alarm corresponding to each zone. It may also be connected to a industrial process control system using the two wire RS-485 Modbus RTU output.Modbus communicationThe unit includes a two wire RS-485 Modbus output which can be enabled to output the status of each zone of the digital location control unit via Modbus RTUASCII protocol. In case of an alarm the location in distance along the cable is also communicated via Modbus.Interconnecting cableThe unit supports the use of a interconnecting cable leader cable in between the control unit and the linear heat detection cable. The interconnecting cable is used in applications where the control unit is not located in the detection zone. The interconnecting cable is then used to connect the control unit in one location with the linear heat detection cable in the protected area. The interconnecting cable is available in 100 m lengths under the product code AAI-0100.Key FeaturesDual Zone - used as Independent or InterlockDesigned for AlarmLine II Digital EN linear heat cableEasy to installIP Rating IP65RoHS compliant CE EN54-282016 certifiedModbus support1km of cable supported per zoneWide supply voltageLow current consumption

GBP 1253.77
1

Kidde Airsense EST-S186 Ceiling Speaker ABS Fire Dome - Diameter 17.5 cm

Kidde Airsense EST-S186 Ceiling Speaker ABS Fire Dome - Diameter 17.5 cm

Kidde Airsense EST-S186 Ceiling Speaker ABS Fire Dome - Diameter 17.5 cmCeiling mounted fire alarm EST-S186 loudspeaker is designed for operations at high acoustic levels and the highest reduction in power supply. Actual wide band high efficiency ensures the best understanding of verbal messages. Its parameters have been carefully selected to comply with suspended ceiling applications both at standard and considerably elevated ceiling-to-floor distance.Thanks to the most advanced technologies EST-S186 loudspeaker combines excellent acoustic parameters and high aesthetics with resistance to mechanical damages. It is distinguished by easy and quick installation.Quality standards and audio characteristics have been confirmed through multiple tests and trials employing such facilities as e.g. echo proof chamber resistance and integrity testing equipment.The EST-S186 loudspeaker ensure a balanced sound which is extremely important in emission of highly understandable speech. The EST-S186 loudspeaker is noticeable thanks to its elegant looks. The loudspeaker part which becomes visible after the installation is covered by a common and aesthetic white paint coat RAL 9003. EST-S186 is equipped with a standardized fire dome made of soft steel and supplied with two cable penetrations with rubber glands. Special jig for sling assembling facilitates quick installation. Ceramic blocks and fireproof wiring coupled with temperature limit fuse are located inside fire dome. The individual power rating is selected by means of connection with applicable transformer branch.EST-S186 loudspeaker equipped with fire dome and thermal protections entirely comply with EN 54-24 Standards. In order to ensure 100 consistency with the highest quality standards we test our loudspeaker following the most meticulous procedures that warrant high parameters of sound emission safety and reliability.In spite of the fact our loudspeaker is designed for the highest reliability under fire conditions their acoustic parameters and attractive low prices make them successful in any and all public address systems.Key FeaturesCompliance with EN 54-24Certificate of Conformity 1438-CPR-0671Compliance with BS5839-8 standard Thermal protectionThe highest level of verbal communication understandingElegant looks6 W transformer allowing a precise selection of loudspeaker output power100 protection of line from breaks and short-circuits

GBP 25.90
1

Kidde Airsense EST-S206B Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 20 cm

Kidde Airsense EST-S206B Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 20 cm

Kidde Airsense EST-S206B Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 20 cmCeiling mounted fire alarm EST-S206B loudspeaker is designed for operations at high acoustic levels and the highest reduction in power supply. Actual wide band high efficiency ensures the best understanding of verbal messages. Its parameters have been carefully selected to comply with suspended ceiling applications both at standard and considerably elevated ceiling-to-floor distance.Thanks to the most advanced technologies EST-S206B loudspeaker combines excellent acoustic parameters and high aesthetics with resistance to mechanical damages. It is distinguished by easy and quick installation.Quality standards and audio characteristics have been confirmed through multiple tests and trials employing such facilities as e.g. echo proof chamber resistance and integrity testing equipment.The EST-S206B loudspeaker ensure a balanced sound which is extremely important in emission of highly understandable speech. The EST-S206B loudspeaker is noticeable thanks to its elegant looks. The loudspeaker part which becomes visible after the installation is covered by a common and aesthetic white paint coat RAL 9003 optionally available other colours RAL palette.EST-S206B is equipped with a standardized fire dome made of soft steel and supplied with two cable penetrations with rubber glands. Special jig for sling assembling facilitates quick installation. Ceramic blocks and fireproof wiring coupled with temperature limit fuse are located inside fire dome. The individual power rating is selected by means of connection with applicable transformer branch.EST-S206B loudspeaker equipped with fire dome and thermal protections entirely comply with EN 54-24 Standards. In order to ensure 100 consistency with the highest quality standards we test our loudspeaker following the most meticulous procedures that warrant high parameters of sound emission safety and reliability.In spite of the fact our loudspeaker is designed for the highest reliability under fire conditions their acoustic parameters and attractive low prices make them successful in any and all public address systems.Key FeaturesCompliance with EN 54-24Certificate of Conformity 1438-CPR-0605Compliance with BS5839-8 standard Thermal protectionThe highest level of verbal communication understandingElegant looks6 W transformer allowing a precise selection of loudspeaker output power100 protection of line from breaks and short-circuits

GBP 40.51
1