Hyfire HFI-IO-404-01 Multiway IO Unit 4 Input 4 Relay Output

Hyfire HFI-IO-422-01 Multiway IO Unit 4 Input 4 Relay Output 2 Supervised Output

Hyfire HFW-TA-05 Intelligent Wireless Heat Detector Libra

Hyfire TAU-OP-01 Taurus Optical Detector

Hyfire TAU-OP-01-BL Taurus Optical Detector Black

Hyfire TAU-MC-01 Taurus Multi-Sensor Detector

Hyfire TAU-MC-01-BL Taurus Multi-Sensor Detector Black

Hyfire TAU-TH-01-BL Taurus Heat Detector Black

Hyfire TAU-TH-01 Taurus Heat Detector

Hyfire HFW-MA-05 Intelligent Wireless Multi-Criteria Detector Libra

Hyfire HFW-PA-05 Intelligent Wireless Optical Smoke Detector Libra

Hyfire HFI-IM-SM-01 Mini Mount Single Supervised Input Module

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay OutputSingle input and single relay output mini module. VMMIC120 contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFIIO- RM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to both remotely monitor a single circuit and control a single ancillary circuit using a set of volt-free changeover relay contacts. The input circuit is monitored for fault condition. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeCan both monitor an input circuit and switch dual volt-free changeover relay contactsFast fit plug-in cable connectionsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised OutputThe module is a single input and single supervised output mini module. The module contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFI-IO-SM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to remotely monitor a single circuit and control a single ancillary circuit using external power. Both input and output circuits are monitored for fault conditions. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeProvides both a fully monitored input and output circuitFast fit plug-in cable connectionsAlternate mechanical variants available to satisfy different applicationsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HFI-CZM-01 Conventional Zone Interface Module

Hyfire HFI-CZM-01 Conventional Zone Interface Module

Hyfire HFI-CZM-01 Conventional Zone Interface ModuleThe VMCZ conventional zone module allows the connection of conventional detectors to a Vega intelligent loop. The module has an onboard relay output driven by the fire alarm control panel. The VCMZ module is designed to provide different current limits.The HFI-CZM-01 conventional zone module is a device permitting to interface an analogue-intelligent addressable loop to a conventional detection zone. The analogue panel sees this device and all the conventional sub-system as a single addressed device on the loop. Conventional zone conditions as normal open and short circuit and alarm are detected by this module and notified to the analogue control panel by the module itself nevertheless this device is not capable of detecting the removal of a sensor from the conventional line. The conventional zone module can be powered in different ways either directly by the analogue detection loop or by an external power supply source. The conventional zone module is capable of monitoring its power supply whether from the analogue loop or external and measure the actual current that is flowing to the conventional zone line giving the analogue control panel full control over the conventional sub-system and its status.Key FeaturesCan be powered either externally or from the loopShort circuit isolator built inAuto addressing capabilityAddressable via HFI-DPT-05 programmer5 year product warrantyAdjustable reset time allowing for greater loop lengthEnd of line options to allow for multiple application from one device

GBP 87.01
1

Hyfire HFI-ABSB-01 Platform Sounder Beacon Base Slave

Hyfire HFI-EBS-06 Enhanced Sounder Base Slave - Altair

Hyfire HFI-EBSB-23W-06 Base SounderVAD Slave EN54 White Lens Altair

Hyfire HFI-EBSB-23R-06 Base SounderVAD Slave EN54 Red Lens - Altair

Hyfire Programming Unit HFI-DPT-05

Hyfire Intelligent Thermal Detector HFI-TA-05