36 results (0,14568 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Gent VIGPLUS-72 Vigilon Plus 1-6 Loop Control Panel with 1 Loop Card

Gent VIGPLUS-72 Vigilon Plus 1-6 Loop Control Panel with 1 Loop Card

GentVIGPLUS-72Vigilon Plus 1-6 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardPlease note This product requires either4 x 12v 24Ah Batteries NP24-12 or 8 x 12v 24Ah Batteries NP24-12.

GBP 3936.43
1

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop Card

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop Card

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardDoes not come with printerPlease note This product requires either4 x 12v 24Ah Batteries NP24-12 or 8 x 12v 24Ah Batteries NP24-12.

GBP 3580.97
1

Gent 803271 Heat Sensor Rate Of Rise

Gent 803371.EX Intrinsically Safe Optical Smoke Detector

Gent 800171 Conventional S-Quad Fixed Heat Detector

Gent SAFE-SS-D-KIT SAFE 2 Button Stainless Steel Plus Interface

Gent SAFE-RED-D-KIT SAFE 2 Button Red Plus Interface

Gent SAFE-WHITE-S-SPARE SAFE 1 Button White Plus Loom

Gent SAFE-SS-D-SPARE SAFE 2 Button Stainless Steel Plus Loom

Gent SAFE-WHITE-D-SPARE SAFE 2 Button White Plus Loom

Gent SAFE-WHITE-D-KIT SAFE 2 Button White Plus Interface

Gent SAFE-RED-D-SPARE SAFE 2 Button Red Plus Loom

Gent 803271.EX Intrinsically Safe Heat Detector Rate of Rise

Gent 803271.EX Intrinsically Safe Heat Detector Rate of Rise

Gent 803271.EX Intrinsically Safe Heat Detector Rate of RiseAutomatic heat detector with a single thermistor to sense the air temperature around the detector. The fast semiconductor sensor for the reliable recognition of fires with a single thermistor to sense the air temperature around the detector.The fast semiconductor quick rate of temperature rise as well as integrated fixed temperature heat function for the recognition of fires with slow temperature rise. Ideal for sensing in environments that are dirty or smoky under normal conditions as well it is unaffected by wind or atmospheric pressure. Intelligent fire detector with decentralized intelligence automatic function self-test emergency mode storage of alarm and operating data alarm display.Soft addressing and separate operational display is only possible when operating an esserbus esserbus-PLus IQ8Quad detector without loop isolator especially for usage in explosion zones. Operation with individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No. 764744.Please use base 8055.Key FeaturesOperating voltage 8 - 42 V DCQuiescent current 19 V DC 40 AAlarm current 9 V DC 18 mAArea to be monitored 30 mHeight to be monitored 7.5 mApplication temperature -20 C - 50 CStorage temperature -25 C - 75 CAir humidity 95 Type of protection IP 40 with base up to IP 43 incl. base optionMaterial ABSColor white similar to RAL 9010Dimensions 117 mm H 49 mm 62 mm incl. base

GBP 179.20
1

Gent SAFE-WHITE-S-KIT SAFE 1 Button White Plus Interface

Gent VIG-NC Network Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful software processing in the panel quickly identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredPlease note This product requires 2 x 12v 12Ah Batteries NP12-12.

GBP 1579.67
1

Gent VIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel amp 1 Loop Card without Printer

Gent VIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel amp 1 Loop Card without Printer

GentVIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel 1 Loop Card without PrinterVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardPlease Note This product requires 2 xYuasa 12V 24AH Battery Inverted Terminals NP24-12.

GBP 2431.50
1

Gent VIGPLUS-24 Vigilon Plus 1-4 Loop Control Panel with 1 Loop Card

Gent VIGPLUS-24 Vigilon Plus 1-4 Loop Control Panel with 1 Loop Card

GentVIGPLUS-24Vigilon Plus 1-4 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardPlease note This product requires2 x 12v 24Ah Batteries NP24-12.

GBP 2681.20
1

Gent S4-34741-50 Obscuration Test Card Set

Gent S4-34741-50 Obscuration Test Card Set

Gent S4-34741-50 Obscuration Test Card SetThe S4-34741-50 is an Obscuration Test Card Set designed for use with Gent Beam Detectors.Honeywell Gents S-Quad Beam Sensors provides an enhanced solution for linear beam detection for applications where point detection is either not practical or economic.Powered and controlled via the loop the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting this ensure the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire. The Gent loop powered beam is certified to EN54 parts 12 and 17.Key FeaturesS-Quad Beam pairs are loop powered supporting 16 pairs per loopEach beam can be set to one of 6 sensitivity states to provide a best fi t for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build-up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software

GBP 32.03
1

Gent S4-34741 Beam Sensor Transmitter

Gent S4-34741 Beam Sensor Transmitter

Gent S4-34741 Beam Sensor TransmitterThe S4-34741 from Gent is a Beam Sensor Emitter.Vigilons loop powered technology allows up to 16 beam pairs to be connected to the same loop circuit each covering a distance of up to 100m without the need for an external Power Supply Unit wiring or interfacing.Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fi re while offering software filters to reduce the number of unwanted alarms.What is a Beam SensorA beam sensor works when theemittersends out abeamof light most often a pulsed infrared visible red or laser that diffuses in all directions filling a detection area. The target then enters the area and deflects part of thebeamback to the receiver.If anything is detected it will signal an alarm.Key FeaturesEach beam can be set to one of 6 sensitivity states to provide a best fi t for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software

GBP 755.02
1

Gent S4-34740 Beam Sensor Pair Transmitter and Receiver Excluding Bracket and Base

Gent S4-34740 Beam Sensor Pair Transmitter and Receiver Excluding Bracket and Base

Gent S4-34740 Beam Sensor Pair Transmitter and Receiver Excluding Bracket and BaseGent S4-34740 S-Quad Addressable Loop Powered Beam Sensor Pair provides an enhanced solution for linear beam detection for applications where Gent S4 Vigilon point detection is either not practical or economic.Powered and controlled via the loop the beam is a market leading device with features such as one man alignment and commissioning which is achieved using the auto gain setting this ensure the optimum alignment is reached.Maintenance of the beam is enhanced with a key operated test feature which simulates the obscuration of the beam in a fire.The Gent loop powered beam is certified to EN54 parts 12 and 17. Compatible with the full range of Vigilon and Nano control panels the S-Quad beam uses the panel software to ensure a fast response to fire while offering software filters to reduce the number of unwanted alarms.Key FeaturesS-Quad Beam pairs are loop powered supporting 16 pairs per loopEach beam can be set to one of 6 sensitivity states to provide a best fit for individual applicationsThe beam provides increased resilience to interference from the sun and other light sourcesRemote key switch provides test facility at ground level without the need to gain access to beams mounted in high areasThe beam incorporates an LED array to indicate signal strength allowing accurate alignment during one person commissioningOptimum sensitivity is maintained by automatic gain setting triggered at the beam during alignmentThe optical lens design is intended to minimise build-up of dust to reduce the maintenance and cleaning requiredThe S-Quad beam is compatible with early versions of the Vigilon Beam using the S-Quad programming base avoiding the need to upgrade to latest control software

GBP 871.37
1