280 results (0,17663 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 590.000.003FC NEO4500E Extension Controller amp 4 Channels Up To 2000W

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller 8 Channels Up To 8000WLDA NEO Extension 8250 is an extension unit for the EN 54-16PAVA system NEO. This extension unit scales the NEO system with 8 more zonesas it includes 8 class D power amplifier channels of 250W at 100V or 70V.Audio is transmitted from the main unit to this extensionunit via a daisy-chain connection by Flexnet and using audio over Ethernet.Therefore it guarantees maximum audio quality and integrity in the signal.The NEO Extension is fully configurable with theNEO-Configurator software included with NEO. It is possible to configureremotely the unit as part of the whole NEO system and create events to performactions in the system triggered by conditions of input level datetimeUDP command a GPIO or button from MPS microphone.Key Features8 class D amplifiers of 250W for 70 or 100V lines8 pre-amp outputs for external PA amplifiers connection.DSP 7-band inputoutput Parametric Equalizer loudness LDAsound enhancer independent volume control per each output channel and audiofilters.Triple Ethernet port for Digital Audio Cobranet remotecontrol and supervision and for escalating the system with NEO-Extensions inredundant daisy-chain mode with Flexnet technology up to 1024 zones.Control for up to 32 attenuators LDA AT6.Integrated frontal loudspeaker for monitoring.12 supervised contact relays for integrationwith Fire Alarm Control Panel.

GBP 4495.06
1

Fireclass 590.000.002FC NEO4250E Extension Controller amp 4 Channels Up To 1000W

Fireclass 601F Conventional Solar Blind Infrared Flame Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke Detector

Fireclass 516.054.011.YFC MR601TEx Conventional High-Performance Optical Smoke DetectorThe MR601TEx detectors react to the whole range of fire products from slow smouldering fires producing visible particles to open flaming fires producing large numbers of very hot smaller sized aerosols. It combines optical and heat detector technology to detect clear burning fire products which hitherto could only be easily detected by ion-chamber detectors.For normal ambient conditions the high-performance optical detector behaves as a normal optical detector. Only when a rapid rise in temperature is detected does the sensitivity of the detector increase and the presence of smoke will confirm a fire condition which will be transmitted as an alarm level.The MR601TEX overcomes the slower response of optical detectors to hot burning fires by increasing the sensitivity of the optical detector when it is associated with a rapid change in temperature. In this way it is intended to become a detector which will suit some of the risks currently covered by ion chamber detectors. Smoke detectors will not detect burning alcohol or other clean burning liquids which do not generate smoke particles.The MR601TEx detector is designed to comply with EN 50 014 and EN 50 020 for intrinsically safe apparatus and is certified to ATEX Code Ex II 1G and Cenelec Code EEx ia IIC T5.Key FeaturesIntelligent Universal SmokeHeatCO detectorLow profile discreet and unobtrusiveSuperior performance and reliabilityDesigned for fast easy installationOptional locking kitMay be used in systems that meet BS5839 Pt 1Integral and remote alarm LEDCertified to ATEX Ex II 1GD and Cenelec Ex ia IIC T5Ex iaD 20 T100oCComplies to EN54-7 for Smoke Detectors and EN54-5 for Heat Detectors

GBP 84.19
1

Fireclass 577.001.037FC 601SBD Conventional Diode Sounder Base

Fireclass 577.001.037FC 601SBD Conventional Diode Sounder Base

Fireclass 577.001.037FC 601SBD Conventional Diode Sounder BaseFireclass offer a choice of functional bases including the 601SBD EN54-3 approved low current sounder base with adjustable volume and tone. They do not require the use of a separate base and fit directly to a standard electrical box or the CTA adaptor plate.The Fireclass range of conventional detector ancillaries have been designed with the needs of the installer in mind. The range includes standard and diode bases sounder beacon and relay bases and the unique time saver ceiling tile adaptor.The 601SBD is for use in detection circuits complying with BS5839 Part 1 which requires that if callpoints are wired after detectors on a zone circuit the removal of a detector will not affect the operation of these callpoints. Removal of the detector should not prevent the sounder operating but will flag up a fault at the control panel.The 601SBD Diode Sounder Base provides eight tone and variable volume settings. It is identified by a green park clip.Key FeaturesAesthetically discreetSuperior performance and reliabilityDesigned for rapid installationManufactured to EN54 part 3.Integral sounder and detector baseVolume and tone adjustable after installationLow Power SynchronisationDo not require use of a standard baseSounder Base provides a sounder function on collective fire detection circuitsOperates independently of the detector circuit and may be used without an associated detectorRequires an external 24Vdc supply and provides eight tones and variable volume settings

GBP 171.46
1

Fireclass FC500IP3 TCPIP Board for FC500 Fire Panels

Fireclass 568.800.034FC HVR800 High Voltage Relay Module In D800 Housing

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF ModuleThe MPM800 is used to provide various expansion capabilities via the remote bus RBUS. The MPM800 is provided as a standalone module but is also incorporated into the circuitry of the OCM800 operator control module to drive the LCD display LEDs key switch and keys on the OCM800 and the operator display module.The OCM800 and MPM800 have an XBUS which can be used to drive up to 80 IO. The MPM800 also has a printer interface for connecting to a serial or parallel printer.An additional printer driver kit is required to allow the MPM800 to drive a printer - a serial isolation module should be used to eliminate earth fault indications caused by some mains connected printers.Up to 15 x MPM modules can be connected to each panel of which 8 can be in the form of OCM800 including the main OCM800 user interface. One OCM800 can also be in the form of an emulated user interface on a remote PC connected via the network or dial up modem.The following IO and LED annunciator modules can be saved from an MPM800Up to 5 x IOB 800 8 in8 out expansion boardUp to 5 x XIOM 800 16 way universal IO boardOne Mimic Panel 80-way LED mimic driver PCBOne 80-way ANN 880 LED mimicOne 40-way ANN 840 LED mimic using red yellow LEDsTwo 20-way COM 820 LED statuscommand modulesThe MPM800 is mounted by plugging directly onto the back of those items markedKey FeaturesFeatures an XBUS whichcan be used to drive up to 80 IOPrinter interface for connecting to a serial or parallel printerDirect Interface to Zonal Displays and other ModulesInterfaces to FIM Board

GBP 230.37
1

Fireclass 557.200.727FC FC500 Repeater

Fireclass 516.016.174FC ProReact EN Digital Sensor Control Unit

Fireclass FC500MFI Multifunctional Interface V3.0

Fireclass 557.202.081FC FOM800 Fibre Optic Module

Fireclass BTM800 Beam Termination Module

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 PointsThe FC503 is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC503 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC503 panel has 3 in 1 loops that can support up to 250 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC503 control panel supports up to 250 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 722.82
1

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 PointsThe FC506is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC506is an out of the box panel which offers thesimplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC506 auto-addressing panel has 6 in 2 loops that can support up to 500 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC506control panel supports up to 500 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features 6 in 2 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 1073.92
1

Fireclass 516.016.016FC ProReact Analogue Controller with Display

Fireclass 516.016.016FC ProReact Analogue Controller with Display

Fireclass 516.016.016FC ProReact Analogue Controller with DisplayProReact Analogue Heat Detector system consists of a control module and four core detection cable designed to interface to a conventional fire alarm panel or DIM800 or DDM800 addressable module. The control module monitors the resistance of specially doped polymers within the sensor cable which change as a function of temperature. An abnormal change in resistance along the detection cable triggers either a Pre- Alarm or Alarm on the interface module.The system is intended to simplify system design and be uncomplicated and straightforward to install. Commissioning of the controller can be done using a laptop computer or through an optional built-in self-programming module. The sensor cable has been designed to be physically and electronically rugged to suite a range of environments with options for PVC Polypropylene or Nylon coatings or a strong stainless steel braid.The ProReact technology offers an alternative solution to heat protection in a wide range of applications and industries from power generation to oil and gas.Typical applicationsCar parksFactories processing plantsWarehousesCable traysConveyor beltsKey FeaturesAlarm Pre-Alarm temperature ranges from 54-100CProgrammable on-site adjustment of sensitivityUp to 500 m continuous lengthAlarm hot-spot length equal to 3 of zone lengthSeparate Alarm and Pre-alarm volt-free outputsNo nomograms or other scales to interpretSimple 3-Step InstallationAmbient temperature compensation maintains alarm temperature accuracySelf-Restorable after fire event up to 125CFlexible cable for easy mechanical installationReliable signalling of open and short circuit conditionsExtrusion and Braiding options to satisfy both mechanical and environmental conditions

GBP 650.09
1