16 results (0,14449 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 PointsThe FC506is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC506is an out of the box panel which offers thesimplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC506 auto-addressing panel has 6 in 2 loops that can support up to 500 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC506control panel supports up to 500 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features 6 in 2 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 1073.92
1

Fireclass 517.001.247FC DX170 Enclosure with 170mm DIN Rail

Fireclass 517.001.248FC DX070 Enclosure with 70mm DIN Rail

Fireclass 2601012FC 6quot Electronic Bell

Fireclass 20-118FC Combined Roshni Sounder Strobe Complete with Deep Base IP65 VID

Fireclass 517.001.302FC MTL5561 2 Channel Galvanic Isolator

Fireclass 516.016.230FC ProReact Dual Height L Clip - Stainless Steel Pack of 100

Fireclass 2601016FC 8quot Electronic Weatherproof Bell

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BCThe 576.440.017FC is a FC445CAV Addressable Wall Sounder VAD BC.This model is compatible with FC510 and FC520 panels and should be used only with those panels. The panel display will show device type of the previous FC410LPBS and FC430LPBSB.The Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV is outdoor versions with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator16 selectable tones for FC445CAVRealistic Conventional Bell Tone2 selectable volumes for FC445CAV2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareCoverage volume code Open ClassDevices per loop Up to 44Flash rate 0.5 1 HzDimensions WxHxD mm 105x153x 97 with I.P. BackBoxSound output 1m Up to 100dBABody colour RedFlash colour WhiteIP code IP55Approvals EN54-3 23 17Housing material PC-ABSOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingPressure Sounder SPL output quoted for 1000 mBarEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesBeacon intensity settings 1Vibration shock corrosion EMC Complies with EN54 series requirementsBeacon flash rates 0.5 and 1 Hz

GBP 251.53
1

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4 Continuity BaseThe DPK6 duct probe units have been developed to detect smoke in ventilation ducts and offer significant benefits in terms of performance and installation. For most applications smoke or combustion products are likely to have travelled some distance ageing the smoke prior to reaching the probe unit. It is therefore normally recommended that an optical smoke detector be fitted and this is often a requirement of building regulations. The DPK6 duct probe units use FC460PH Multi Sensor Smoke Detectors.The DPK6 Duct Probe units are not normally mounted directly inside ducts because the airflow only allows the detector to sample air from a small section of the duct and such detectors would rapidly become dirty. Instead ducting is protected by the use of probe units which gather air from a cross section of the duct and pass it through a smoke detector head.The system comprises only one single duct probe tube which improves efficiency and reduces installation time. The DPK6 duct smoke detector housing is designed to comply with the stringent demands of new European standard EN 54-27. The system fulfils all the requirements for safe fire detection with airflow speeds from 15 ms to 20 ms. For the airflow through the adaptor to be representative of the airflow in the ventilation duct the detector should be installed at a place where normally flow meters etc. are sited.Key FeaturesDPK6 for use with FC460PH with built-in 4B-C 4 continuity base.Designed to comply with EN 54-27.One-pipe air sampling system.Patented Cap-up Venturi pipe and duct housing.Test hole on cover.Simple installation.Sensitive flow indicator.Simple service and maintenance.Range of aluminium probe tubes are available for ducts up to 2700 mm.

GBP 134.30
1