60 results (0,17785 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 517.001.196FC UC2 4 Way Barrier Housing

Fireclass COM820 - 20 Way Status Command Module

Fireclass 508.032.730FC Fireclass Essential 2 Zone Panel

FC410QRM Fireclass 4-Way Quad Relay Module

FC410QIO Fireclass 4 Way Input Output Module

Fireclass 577.001.038FC 602SBD Conventional 2 Wire Sounder Base

Fireclass Prescient 3 Status Lamp Unit SLU 2

Fireclass 557.202.018FC ANN820 40-Way 20 x Red Yellow 20 x Green Yellow LED Module

Fireclass 508.070.002FC FCG Software Licence 2-4 Panel

Fireclass 577.001.036FC 602SB Conventional 2 Wire Sounder Base

Fireclass 517.001.302FC MTL5561 2 Channel Galvanic Isolator

Fireclass 516.016.027FC Digital Interface 2-Zone Monitor Module

Fireclass 516.016.027FC Digital Interface 2-Zone Monitor Module

Fireclass 516.016.027FC Digital Interface 2-Zone Monitor ModuleA Unique and Flexible dual zone Digital LHD Interface Monitor Module offering advanced functionality to traditional Digital LHD systems.A further important addition to Thermocables world leading family of digital linear heat detection technologies the ProReact Interface Monitor Module is designed to work with the ProReact Digital Linear Heat Detection Cable and effectively monitor up to two zones at any one time.The Digital Interface Monitor Module is unique in being approved to the UL864 10th edition standard the most recent revision to the UL standard for fire alarm control panels and accessories. It has been designed and tested against the stringent requirements of the 10th edition including new tests to confirm the integrity of the software in the device. The Digital Interface Monitor Module simultaneously monitors two zones of Digital LHD cable for an alarm or fault condition. If an overheat or fire situation triggers either zone of the Digital LHD cable the Module automatically calculates and displays the distance along the cable in feet and metres to the alarm point. The two zones can operate independently of each other or in interlockcoincidence detection mode to eliminate the possibility of false alarms.The Module is intended to be installed between the Digital Linear Heat Detection cable and a conventional or addressable fire alarm control panel. An RS-485 Modbus RTU output also allows direct connection into a PLC or other process control system.Typical ApplicationsPower generation industriesOil and gas industriesMinesCold storage and industrial freezersFloating roof storage tanksTunnelsCable traysWarehousingKey FeaturesAdvanced functionality for traditional Digital LHD systemsPinpoints exact location of an incident and responds immediatelySimultaneous monitoring of up to two zonesPower indicator fault and alarm lights for each zoneVolt-free outputs for fault and alarm corresponding to each zoneCan be connected to an industrial process control system using the two-wire RS485 Modbus RTU outputBuilt-in sounder for audible annunciationInterlockCoincidence detection eliminates the possibility of false alarms by requiring both LHD cables to trigger before transmitting an alarmUL CE RoHS approved to meet end user specificationsSimultaneous monitoring of up-to two zones increases potential applications. For example pre-alarm on one zonealarm on the other fault-tolerant triggering of alarm both zones must activate before alarm at panelImmediately pinpoints exact location and responds to an incidentCompatible with Thermocables ProReact Digital LHD cableCan be retro-fitted to existing installationsCost effectively increases functionality and performanceConnects to addressable fire alarm control panels for fast response to faultsLow installation and maintenance costs reduce total cost of ownershipReliability through design approvals and 3 year warranty

GBP 515.16
1

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF Module

Fireclass 557.202.012FC MPM800 Multi-Purpose IF ModuleThe MPM800 is used to provide various expansion capabilities via the remote bus RBUS. The MPM800 is provided as a standalone module but is also incorporated into the circuitry of the OCM800 operator control module to drive the LCD display LEDs key switch and keys on the OCM800 and the operator display module.The OCM800 and MPM800 have an XBUS which can be used to drive up to 80 IO. The MPM800 also has a printer interface for connecting to a serial or parallel printer.An additional printer driver kit is required to allow the MPM800 to drive a printer - a serial isolation module should be used to eliminate earth fault indications caused by some mains connected printers.Up to 15 x MPM modules can be connected to each panel of which 8 can be in the form of OCM800 including the main OCM800 user interface. One OCM800 can also be in the form of an emulated user interface on a remote PC connected via the network or dial up modem.The following IO and LED annunciator modules can be saved from an MPM800Up to 5 x IOB 800 8 in8 out expansion boardUp to 5 x XIOM 800 16 way universal IO boardOne Mimic Panel 80-way LED mimic driver PCBOne 80-way ANN 880 LED mimicOne 40-way ANN 840 LED mimic using red yellow LEDsTwo 20-way COM 820 LED statuscommand modulesThe MPM800 is mounted by plugging directly onto the back of those items markedKey FeaturesFeatures an XBUS whichcan be used to drive up to 80 IOPrinter interface for connecting to a serial or parallel printerDirect Interface to Zonal Displays and other ModulesInterfaces to FIM Board

GBP 230.37
1

Fireclass FC702S 1-2 Loop Touchscreen Fireclass Control Panel

Fireclass FC702S 1-2 Loop Touchscreen Fireclass Control Panel

Fireclass FC702S 1-2 Loop Touchscreen Fireclass Control PanelThe FireClass range of fire alarm control panels provide a great deal of flexibility in terms of hardware configuration scalability and feature set. They are easy to operate easy to install easy to service and provide the system designer with a wide range of practical engineering solutions. Remote connectivity and backwards compatibility make it a future proof investment with long term support and reduced life time cost.The two loop addressable panel from FireClass is a highly featured digital addressable fire alarm system with an advanced TFT colour touch-screen user interface that is ergonomically engineered specifically for fire alarm control. Operation of the touch screen is possible with or without gloves and provides easy-to-use intuitive user controls including keyless log-on using RFID cards.The FC702S is housed in a compact shallow enclosure whilst the FC702D has a deep housing to accommodate larger batteries for extended standby periods. Each panel can support 250 addresses in total and panels can be seamlessly networked together making it suitable for a range of applications.The robust FireClass loop protocol can operate in the harshest of environments. Essential for system upgrades existing cables can be reused significantly reducing the cost of replacing a system. Ample loop power is available to meet the increasing demand for visual alarms in addition to traditional audible alarms. Practicalities such as the layout of a building or the number of alarm devices will often dictate the useable size of a detection loop and can result in unused capacity and the need for additional hardware.In order to optimise loop capacity FireClass offers a system design solution. Each addressable loop can be connected as one high power HP loop or two shared power SP loops. This provides the system designer the flexibility of allocating all available power and 250 addresses to the HP loop or to share resources across two SP loops. This level of optimisation can significantly reduce total installed system cost.Key Features8.4 TFT colour touch screen multilingual user interface -architecturally attractive and fully programmableErgonomic Icon Display - simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summary information - instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent usersUser configurable on screen site maps - no need for additional site plansProgrammable graphic quiescent display - opportunity for customer brandingComprehensive point management and disable functions - gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags identifies and logs user actionsFlexible single or dual hardware loop configurations - optimise loop power and address capacityCompact shallow housing or deep housing - designed for standard or extended battery standby period

GBP 1384.00
1

Fireclass FC702D 1-2 Loop Touchscreen Fireclass Control Panel Deep Enclosure

Fireclass FC702D 1-2 Loop Touchscreen Fireclass Control Panel Deep Enclosure

Fireclass FC702D 1-2 Loop Touchscreen Fireclass Control Panel Deep EnclosureThe FireClass range of fire alarm control panels provide a great deal of flexibility in terms of hardware configuration scalability and feature set. They are easy to operate easy to install easy to service and provide the system designer with a wide range of practical engineering solutions. Remote connectivity and backwards compatibility make it a future proof investment with long term support and reduced life time cost.The two loop addressable panel from FireClass is a highly featured digital addressable fire alarm system with an advanced TFT colour touch-screen user interface that is ergonomically engineered specifically for fire alarm control. Operation of the touch screen is possible with or without gloves and provides easy-to-use intuitive user controls including keyless log-on using RFID cards.The FC702S is housed in a compact shallow enclosure whilst the FC702D has a deep housing to accommodate larger batteries for extended standby periods. Each panel can support 250 addresses in total and panels can be seamlessly networked together making it suitable for a range of applications.The robust FireClass loop protocol can operate in the harshest of environments. Essential for system upgrades existing cables can be reused significantly reducing the cost of replacing a system. Ample loop power is available to meet the increasing demand for visual alarms in addition to traditional audible alarms. Practicalities such as the layout of a building or the number of alarm devices will often dictate the useable size of a detection loop and can result in unused capacity and the need for additional hardware. In order to optimise loop capacity FireClass offers a system design solution.Each addressable loop can be connected as one high power HP loop or two shared power SP loops. This provides the system designer the flexibility of allocating all available power and 250 addresses to the HP loop or to share resources across two SP loops. This level of optimisation can significantly reduce total installed system cost.Key Features8.4 TFT colour touch screen multilingual user interface -architecturally attractive and fully programmableErgonomic Icon Display - simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summary information - instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user training and provides support for infrequent usersUser configurable on screen site maps - no need for additional site plansProgrammable graphic quiescent display - opportunity for customer brandingComprehensive point management and disable functions - gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters - effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags identifies and logs user actionsFlexible single or dual hardware loop configurations - optimise loop power and address capacityCompact shallow housing or deep housing - designed for standard or extended battery standby period

GBP 1474.70
1

Fireclass 508.031.753FC BAW75T-24 PSU 24V 2.7A Extended Input Voltage Range