Fike FIK-IR3-H2-HD-AS11 Triple IR Hydrogen Flame Detector With HD Video Output

Fike FIK-IR3-H2-HD-AS11 Triple IR Hydrogen Flame Detector With HD Video Output

Fike FIK-IR3-H2-HD-AS11 Triple IR Hydrogen Flame Detector With HD Video OutputThe IR3-H2-HD flame detector provides ultra-fast response high performance and reliable detection for a number of fires found in Energy Transition applications. The detector addresses slow growing fires as well as fast eruptions of fire using improved IR3 technology. The detector operates in all weather and light conditions.The detector provides high-definition HD video output of the monitored area with clear imaging of a fire event and of personnel at distances up to 100 ft. 30m. This allows the rescue team to be aware of the exact situation before entering the hazardous area. Video and data of events are stored and saved quickly to non-volatile memory for post incident investigation. The recordings start one minute before detection and continue for up to four minutes.Key FeaturesHigh immunity to false alarm including arc weldingUltra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosionsDetects hydrogen ammonia methane Syngas flames 3 infrared wavelengths with clear separation.Five selectable sensitivity levelsHD or composite video output with automatic HD video recording of eventsDataEvent logger alarms faults and other relevant events are logged to non-volatile memoryUniversal outputs 3 and 4 wire 4-20 mA sinksource Fire Auxiliary and Fault Relays RS485 port using Modbus RTUBuilt-in-Test BIT Automatic and manual self-test of window cleanliness and overall detector operationWindow heater to avoid condensation and icingStainless steel tilt mount adjustable horizontallyvertically

GBP 4874.34
1

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008

Fike TwinflexPro2 2 Wire 8 Zone Control Panel CPR Compliant - 505-0008The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 358.10
1

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004

Fike TwinflexPro2 2 Wire 4 Zone Control Panel CPR Compliant - 505-0004The TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 277.88
1

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR Compliant

Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel CPR CompliantThe TwinflexPro2 panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol. The TwinflexPro2 panel is available in 24 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro2 is able to recognise and separately identify between smoke detector heat detector and a manual call point alarm.The panel also monitors each zone for detector head removal device fault End of line fault and open or short circuit fault. The panel provides two monitored outputs that may be configured as conventional sounder circuits a volt free common fire relay and a volt free common fault relay. There are also two multifunction latchingnon-latching inputs and one monitored input programmable with options such as Class-Change and Remote fire. The control panel also incorporates an integral power supply unit and requires 2 x 12V 3.2Ah batteries to provide up to 72-hour standby times.The panel features a 500-event log daynight mode alarm confirmation and delay programming options that can be configured using the keypad or via PC driven OSP software. The TwinflexPro2 panel is no longer only compatible with Fikes Twinflex devices with the addition of our conventional zone card a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8.Unlike most conventional fire alarm systems which require separate pairs of cables for detector zones and sounder circuits the Twinflex system requires one 2-core screened cable for each zone to accommodate both detection devices and sounders when using Twinflex devices.Key Features4 line x 20 character LCD displayAbility to differentiate between smoke detector heat detector or a manual call point alarmsAlarm confirmation featureAvailable in 2 4 and 8 zone panel versionsRS485 Connection to up to 8 Repeater panelsHighlighted selection menuEvent log storing up to 500 events3 enhanced test modesAllows detectors and sounders to be installed on the same pair of wiresUp to 32 devices per zoneBuilt-in EOL capability in all devices7 modes of detectionZone can be configured to daynight detection modeDelay programming optionsTwinflexPro2 ProtectsBed BreakfastsApartmentsFlatsHouses in Multiple Occupation HMORestaurantRetail StoresHistorical BuildingsMuseums Office Buildings

GBP 230.99
1