60 results (0,15189 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec AML Lectern Microphone

C-Tec AMLS Lectern Short Stemmed Microphone

C-Tec CFP EN54-13 Interface Board BF354

C-Tec RXTI2 Hearing Loop Listener

C-Tec CA455AW CA O Class Base Voice Sounder VAD White

C-Tec BF430CEASW EA Wall Sounder - Self Testing - White

C-Tec CA456AB CA Base Sounder VAD Black

C-Tec CA457AW CA C Class Base Voice Sounder VAD - White

C-Tec CA470W CA Manual Call Point Surface - White

C-Tec CA470Y CA Manual Call Point Surface - Yellow

C-Tec BF375PE Unregulated Double Gang Door Release PSU

C-Tec CA470B CA Manual Call Point Surface - Blue

C-Tec CA470GR CA Manual Call Point Surface - Green

C-Tec NC889ERM Conventional Multi-Purpose Call Latch Module

C-Tec CFP Network Driver Card CFP761

C-Tec NC944 Four Zone Call Controller with Mute Reset Button

C-Tec NC944 Four Zone Call Controller with Mute Reset Button

C-Tec NC944 Four Zone Call Controller with Mute Reset ButtonThe NC944 Four Zone Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons are also provided to allow the user to Reset or Mute standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button if enabled cancels all standard calls.Pressing the Controllers Mute Button if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesAn attractively-designed four zone call controller cw mute and reset buttonsFully compatible with C-TECs entire range of 800 Series Call System componentsCapable of indicating standard constant tone and emergency intermittent tone callsRequires a separate NC930 12V 250mA PSUIncludes four zonal alarm LEDs RESET and MUTE buttonsTwo open collector outputs Emergency and Aux OutUp to two NC944s can be connected to one NC930 PSU to create a mini-call system of up to 8 zonesMounts on a standard 25mm UK double gang back box

GBP 75.00
1

C-Tec CA447ASR CA Wall Voice Sounder VAD Shallow Red

C-Tec QT636 Quantec Interface Unit with Remote Socket

C-Tec CA416B CA Optical Smoke Detector - Black