18 results (0,14666 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec EVC301JP Single Gang Jack Plate

C-Tec BF364 Single Gang Locking Jack Socket

C-Tec BF375P Unregulated Door Release PSU on Double Gang Plate

C-Tec BF367 Auxiliary Device Isolator single gang

C-Tec BF367 Auxiliary Device Isolator single gang

BF367 Auxiliary Device Isolator single gangThe BF367 allows a 24V d.c. output from a fire alarm control panel to be remotely isolated to prevent external equipment such as auto diallers roller shutter doors etc from operating. This is a particularly useful function during routine test and maintenance as it safeguards against the inadvertent and potentially hazardous triggering of auxiliary equipment.To aid location the BF367s front label has a white write on panel allowing installers to add their own personalised text such as equipment locations. The unit will fit on 25mm deep flush or surface mount back boxes.Key FeaturesThe BF367 incorporates an isolating key switch and a high intensity amber LEDThe switch circuit has been designed so that if monitoring is used on the 24V d.c. output being controlled a fault condition will show at the fire panel when the BF367s key switch is in the ISOLATED position note that the key can be removed from the key switch in both the ON and ISOLATED positionsThe units amber LED can also be set-up to illuminate when the key switch is in the ISOLATED position provided sufficient voltage is presentAllows a 24 VDC output from a fire alarm control panel to be remotely isolated to prevent autodiallers water sprinklers rollershutters etc. from activatingDesigned so that if monitoring is used on the 24 VDC output being controlled a fault condition will show at the fire panel when the device is IsolatedLabel includes a white write on area allowing installers to add equipment locationsFits on standard UK 25mm flush or surface mount back boxes

GBP 21.18
1

C-Tec NC899IRR Conventional Key Switch Reset Point

C-Tec NC804DE Conventional Emergency Call Reset Point with Button Reset

C-Tec NC806C Conventional Overdoor Light

C-Tec NC802DB Conventional Call Point with Button Reset and Remote Socket

C-Tec NC894DKB Conventional Isolatable Monitoring Point with Button Reset and Door Contacts

C-Tec NC806CS Conventional Overdoor Light amp Sounder

C-Tec NC802DEB-12 Conventional Emergency Call Point with Button Reset and Remote Socket

C-Tec SPE0849000 NC802DB cw QT602E Label

C-Tec NC809DBBT Conventional Accessible Toilet Reset Point with Sounder

C-Tec BF391 Isolated Failsafe Monitor Unit

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network SplitterQuantec utilises a unique data protocol that works down two wires andamaximum of 255 addressable devices can be connected to a Quantec Controller dependent on network topology.Addressable devices require 2 network connections. Slave devices such as slave ceiling pullsandslave overdoor lights connect to Quantec via a master call point master ceiling receiver monitoring point or universal programming device using 2 3 or 4 cores of stranded security cable.Wiring must bemade in a Spine and Limb configuration using one or more QT603 network splitters. This allowsthe use of ordinary unscreened cable which simplifies installation fault-finding and commissioning.Key FeaturesAn essential wiringinstallation aid for C-TECsQuantec Addressable Call System.Helps protect against open and short circuit faults and reduces the risk of volt drop.Includes one input and one output connection for Quantecs Spine wiring typically 1.5-2.5mm TE and sixfused 400mA limb connections for the wiring of individual circuits containing Quantecs fielddevices typically 4 core stranded security cable.At least one QT603 is required perQuantec system the more you use the easier it will beto program and fault-find.Install one QT603 per corridor junction locate at the end of the corridor nearest to the Quantec Controller.Ifthe corridor is longer than 50m install the splitter in the centre of the corridor to reduce wiring runs.Mounts on a standard 25mm UK double gang back box.Power and Fault indicators.Max.60 addressable devices per QT603.

GBP 29.40
1