40 results (0,14100 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall ECLIPSE 4 CASE BATT BOX BVECASE4BATT

Baldwin Boxall Relay 5A 8 Way PCB B81R

Baldwin Boxall 100W Volume Controls with Override Relay BVC100

Baldwin Boxall 6W Volume Controls with Override Relay BVC6

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8Our telephone interface units enable staff to make public address announcements from their own desk telephone. The free-standing units act as an interface between the analogue telephone system and the amplifier.Key FeaturesOperated by simply dialling the BT5BT8 extension number.Each unit is supplied with an IEC mains lead.Can be used to broadcast live announcements.Additional facility enables the user to pre-record an announcement. This reduces the risk of feedback where the telephone is adjacent to a loudspeaker.When connected to a telephone system with MF signalling the BT8 enables the user to select up to eight zones via the telephone keypad.An internal selector determines if the recorded message is played once or twice.Can be wired into any two-wire analogue extension port via a designated master extension socket. Another option is to connect the unit to the paging port available on most modern telephone switches. However they are not designed to operate on keyphone system extension ports.Outputs are selectable from line or microphone level.Signal output and zone select connections are via a 25 way D connector.Compatible with our BDM300 range of desk microphones connected via the BMS25 socket box supplied with the microphone.We recommend using our B81R relay unit for the zone select switching.Please note the BT8 is not approved for direct connection to the BT network. Under general approval NSG23J100003 it may be connected to a port on a telephone switch PABX. This unit should only be used with a switchable amplifier input.

GBP 1050.54
1

Baldwin Boxall 4-way Disabled Toilet Alarm Control Panel DTA4

Baldwin Boxall 4-way Disabled Toilet Alarm Control Panel DTA4

Baldwin Boxall 4-way Disabled Toilet Alarm Control Panel DTA4Disabled toilet alarms are used as a method for people to call for assistance following a fall or other emergency. They are generally installed in disabled toilet cubicles however they can be used in other places such as bedrooms.Our 4-way controller together with our toilet alarm kits forms a fully compliant to BS8300 easy-to-use disabled toilet alarm solution.The controller has many advantages over similar products on the market today.Key FeaturesIndependent call acceptacknowledge button for each toilet alarm connected.Monitored system with fault LED to indicate if a short or open condition is detected.Independent fault indicators for each line.The panel has a built-in mains supply and is simply installed via a fused spur 3A switched connection to a separate power supply is not required. An LED on the panel confirms that the system is powered and available for use.Up to ten of the panels can be daisy chained for larger systems without the need for any additional power source.A separate relay output enables connection to an external beacon providing the opportunity to add a remote indicator to alert staff in a different area.Full compliance to BS8300 with an acknowledge feature to reassure the caller that help is on the way both audible and visual alarms change at the point of call when acknowledge button is pressed.The system has a programmable alarm re-sound feature. This will operate if a call has been acknowledged at the control unit but is not reset at the point of call within the specified time.Space to independently label each zone for easy identification of the alarm call.Choice of a white or stainless-steel finish as standard.For ease of installation the panel fits into a standard double gang back box not supplied.

GBP 224.08
1

Baldwin Boxall 4 Way Toilet Alarm Control Panel SSteel DTA4S

Baldwin Boxall 4 Way Toilet Alarm Control Panel SSteel DTA4S

Baldwin Boxall 4 Way Toilet Alarm Control Panel SSteel DTA4SDisabled toilet alarms are used as a method for people to call for assistance following a fall or other emergency. They are generally installed in disabled toilet cubicles however they can be used in other places such as bedrooms.Our 4-way controller together with our toilet alarm kits forms a fully compliant to BS8300 easy-to-use disabled toilet alarm solution.The controller has many advantages over similar products on the market today.Key FeaturesIndependent call acceptacknowledge button for each toilet alarm connected.Monitored system with fault LED to indicate if a short or open condition is detected.Independent fault indicators for each line.The panel has a built-in mains supply and is simply installed via a fused spur 3A switched connection to a separate power supply is not required. An LED on the panel confirms that the system is powered and available for use.Up to ten of the panels can be daisy chained for larger systems without the need for any additional power source.A separate relay output enables connection to an external beacon providing the opportunity to add a remote indicator to alert staff in a different area.Full compliance to BS8300 with an acknowledge feature to reassure the caller that help is on the way both audible and visual alarms change at the point of call when acknowledge button is pressed.The system has a programmable alarm re-sound feature. This will operate if a call has been acknowledged at the control unit but is not reset at the point of call within the specified time.Space to independently label each zone for easy identification of the alarm call.Choice of a white or stainless-steel finish as standard.For ease of installation the panel fits into a standard double gang back box not supplied.

GBP 252.20
1

Baldwin Boxall Consisting BVOC4MS. ampBY7.2 BVOC4MS

Baldwin Boxall Consisting BVOC4MS. ampBY7.2 BVOC4MS

Baldwin Boxall Consisting BVOC4MS. BY7.2 BVOC4MSOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 1926.89
1

Baldwin Boxall Consisting BVOC48S.BY60FT amp BVOBATT2 BVOC48S

Baldwin Boxall Consisting BVOC48S.BY60FT amp BVOBATT2 BVOC48S

Baldwin Boxall Consisting BVOC48S.BY60FT BVOBATT2 BVOC48SOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 4916.11
1

Baldwin Boxall Consisting BVOC64S.BY90 amp BVOBATT2 BVOC64S

Baldwin Boxall Consisting BVOC64S.BY90 amp BVOBATT2 BVOC64S

Baldwin Boxall Consisting BVOC64S.BY90 BVOBATT2 BVOC64SOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 5360.64
1

Baldwin Boxall Consisting BVOC96S.BY125 amp BVOBATT3 BVOC96S

Baldwin Boxall Consisting BVOC96S.BY125 amp BVOBATT3 BVOC96S

Baldwin Boxall Consisting BVOC96S.BY125 BVOBATT3 BVOC96SOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 6755.02
1

Baldwin Boxall Consisting BVOC32MS. ampBY24 BVOC32MS

Baldwin Boxall Consisting BVOC32MS. ampBY24 BVOC32MS

Baldwin Boxall Consisting BVOC32MS. BY24 BVOC32MSOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 2874.91
1

Baldwin Boxall Consisting BVOC112S.BY125 amp BVOBATT3 BVOC112S

Baldwin Boxall Consisting BVOC112S.BY125 amp BVOBATT3 BVOC112S

Baldwin Boxall Consisting BVOC112S.BY125 BVOBATT3 BVOC112SOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 7426.34
1

Baldwin Boxall Consisting BVOC8MS. ampBY18 BVOC8MS

Baldwin Boxall Consisting BVOC8MS. ampBY18 BVOC8MS

Baldwin Boxall Consisting BVOC8MS. BY18 BVOC8MSOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 1991.30
1

Baldwin Boxall Consisting BVOC80S.BY90 amp BVOBATT2 BVOC80S

Baldwin Boxall Consisting BVOC80S.BY90 amp BVOBATT2 BVOC80S

Baldwin Boxall Consisting BVOC80S.BY90 BVOBATT2 BVOC80SOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 6598.97
1