22 results (0,13750 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aritech ATS1473-5 Heavy Duty Smart Key Fob - Pack Of 5 - Blue - For Use With ATS119x Readers And ATS111x Keypads

Aritech ATS1190 ATS Smart Card Reader With Output amp RTE Supplied with 2.5 M Of Cable

Aritech ATS1190 ATS Smart Card Reader With Output amp RTE Supplied with 2.5 M Of Cable

Aritech ATS1190 ATS Smart Card Reader With Output RTE Supplied with 2.5 M Of CableThe ATS1190 smart card readers connect directly on the RS485 data bus of the control panel or 4-Door Controller and may be configured and addressed via a LCD keypad. Some security options Site code 4-byte security code are only programmable via TITAN and configuration cards. The ATS1190 is supplied standard with a white removable dress cover which can be interchanged with one of four other colours availableHigh quality cards key fobsBoth the smart chip and antenna are embedded inside the cards fobs. Printing is possible on the cards using any industry standard printer. The ATS1472 cards feature a programmable magnetic stripe for Time Attendance or other applications.Security FeaturesThe ATS smart card technology has the ability to program a unique 268 million 4-byte combination security code values from 0 through 127 are applicable for EMEA. This allows the memory card to unlockopendisarm based on three keys the card number the Site code and the 4-byte security code. Once a 4-byte security code has been created downloaded to the programmer and the cards it is not possible to read the memory on the card or even recognise the card memory at any other reader or TITAN and programmer combination. Communications between TITAN and the programmer may also be password protected to prevent the 4-byte security code from being uploaded from the programmer into another PC running TITAN.Key FeaturesFull epoxy filled weather proof constructionStandard white snap-on cover optional red black beige grey

GBP 200.58
1

Aritech ATS1471-5 Heavy Duty Smart Key Fob - Pack Of 5 Fobs - Designer Style - Black

Aritech AS619 Outdoor Siren

Aritech AS631V Outdoor Siren Inox VDS - Red Lens Beacon

Aritech ACT455 Mifare EV2 PVC Card Empty Pack Of 25 For Use With ATS Programmer No SW

Aritech ACL585 Keypad Standalone Aluminium Slim - Vandal-Proof

Aritech ATS1192 ATS Heavy Duty Smart Card Reader With Output amp RTE

Aritech ATS1192 ATS Heavy Duty Smart Card Reader With Output amp RTE

Aritech ATS1192 ATS Heavy Duty Smart Card Reader With Output RTEThe ATS1192 smart card reader connect directly on the RS485 data bus of the control panel or 4-Door Controller and may be configured and addressed via a LCD keypad. Some security options Site code 4-byte security code are only programmable via TITAN and configuration cards.The ATS1192 is mainly used for outdoor applications and due to the waterproof construction it is suitable for use in harsh environments.High quality cards key fobsBoth the smart chip and antenna are embedded inside the cards fobs. Printing is possible on the cards using any industry standard printer. The ATS1476 cards feature a programmable magnetic stripe for Time Attendance or other applications.Security featuresThe ATS smart card technology has the ability to program a unique 268 million 4-byte combination security code values from 0 through 127 are applicable for EMEA. This allows the memory card to unlockopendisarm based on three keys the card number the Site code and the 4-byte security code. Once a 4-byte security code has been created downloaded to the programmer and the cards it is not possible to read the memory on the card or even recognise the card memory at any other reader or TITAN and programmer combination. Communications between TITAN and the programmer may also be password protected to prevent the 4-byte security code from being uploaded from the programmer into another PC running TITAN.ReadWrite encryptionThe ATS Smart card technology also features an exclusive readwrite encryption. When a card is presented at a reader data are downloaded into the reader encrypted and re-written back into the card. The readers can also be configured to operate in stand-alone or connected to control devices like office equipment or vending machines. This function enables credits to be assigned on user cards and deducted by the readers purely on a usage basis. Up to 65535 credits may be allocated in up to 4 different banks with 16 access levels and 4 locations. The reader determines of which bank credits have to be deducted and the number of credits per valid presentation.Key FeaturesFull epoxy filled weather proof constructionHeavy-duty versionCompatible with Axon and Advisor Advanced panels

GBP 210.16
1

Aritech ATS1192X4 ATS Heavy Duty Smart Card Reader x 4

Aritech ATS1192X4 ATS Heavy Duty Smart Card Reader x 4

Aritech ATS1192X4 ATS Heavy Duty Smart Card Reader x 4The ATS1192 smart card reader connect directly on the RS485 data bus of the control panel or 4-Door Controller and may be configured and addressed via a LCD keypad. Some security options Site code 4-byte security code are only programmable via TITAN and configuration cards.The ATS1192 is mainly used for outdoor applications and due to the waterproof construction it is suitable for use in harsh environments.High quality cards key fobsBoth the smart chip and antenna are embedded inside the cards fobs. Printing is possible on the cards using any industry standard printer. The ATS1476 cards feature a programmable magnetic stripe for Time Attendance or other applications.Security featuresThe ATS smart card technology has the ability to program a unique 268 million 4-byte combination security code values from 0 through 127 are applicable for EMEA. This allows the memory card to unlockopendisarm based on three keys the card number the Site code and the 4-byte security code. Once a 4-byte security code has been created downloaded to the programmer and the cards it is not possible to read the memory on the card or even recognise the card memory at any other reader or TITAN and programmer combination. Communications between TITAN and the programmer may also be password protected to prevent the 4-byte security code from being uploaded from the programmer into another PC running TITAN.ReadWrite encryptionThe ATS Smart card technology also features an exclusive readwrite encryption. When a card is presented at a reader data are downloaded into the reader encrypted and re-written back into the card. The readers can also be configured to operate in stand-alone or connected to control devices like office equipment or vending machines. This function enables credits to be assigned on user cards and deducted by the readers purely on a usage basis. Up to 65535 credits may be allocated in up to 4 different banks with 16 access levels and 4 locations. The reader determines of which bank credits have to be deducted and the number of credits per valid presentation.Key FeaturesFull epoxy filled weather proof constructionHeavy-duty versionCompatible with Axon and Advisor Advanced panelsPack of 4

GBP 793.42
1

Aritech ATS1476 Hitag II Dual Card With Magstripe Pack Of 10 Cards

Aritech ATS1190X4 ATS Smart Card Reader X 4

Aritech ATS1190X4 ATS Smart Card Reader X 4

Aritech ATS1190X4 ATS Smart Card Reader X 4The ATS1190X4 is an economic 4 pack of ATS1190 smart card readers. The reader connect directly on the RS485 data bus of the control panel or 4-Door Controller and may be configured and addressed via a LCD keypad. Some security options Site code 4-byte security code are only programmable via TITAN and configuration cards. The ATS1190 is supplied standard with a white removable dress cover which can be interchanged with one of four other colours available see Ordering Information.High quality cards key fobsBoth the smart chip and antenna are embedded inside the cards fobs. Printing is possible on the cards using any industry standard printer. The ATS1472 cards feature a programmable magnetic stripe for Time Attendance or other applications.Security FeaturesThe ATS smart card technology has the ability to program a unique 268 million 4-byte combination security code values from 0 through 127 are applicable for EMEA. This allows the memory card to unlockopendisarm based on three keys the card number the Site code and the 4-byte security code. Once a 4-byte security code has been created downloaded to the programmer and the cards it is not possible to read the memory on the card or even recognise the card memory at any other reader or TITAN and programmer combination. Communications between TITAN and the programmer may also be password protected to prevent the 4-byte security code from being uploaded from the programmer into another PC running TITAN.ReadWrite EncryptionThe ATS Smart card technology also features an exclusive readwrite encryption. When a card is presented at a reader data are downloaded into the reader encrypted and re-written back into the card. The readers can also be configured to operate in stand-alone or connected to control devices like office equipment or vending machines. This function enables credits to be assigned on user cards and deducted by the readers purely on a usage basis. Up to 65535 credits may be allocated in up to 4 different banks with 16 access levels and 4 locations. The reader determines of which bank credits have to be deducted and the number of credits per valid presentation.Key FeaturesFull epoxy filled weather proof constructionStandard white snap-on cover optional red black beige greyPacked by 4Compatible with Axon and Advisor Advanced panelsSpecified cable - Aritech WCAT 5254 or equivalent

GBP 751.70
1

Aritech ACT457 Mifare Ev2 Key Fob Empty Pack Of 25 For Use With ATS Programmer No SW

Aritech 2X-AF1-S-99 2X-A Addressable Fire Panel Small Cabinet 1 Loop

Aritech 2X-AF1-S-99 2X-A Addressable Fire Panel Small Cabinet 1 Loop

Aritech 2X-AF1-S-99 2X-A addressable Fire Panel Small Cabinet 1 LoopThe 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any colour and the easy to remove electronics will support in this matter. The gently lined door with the intuitive dark inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial.Key Features1 High Power Loop with 500 mA per loopHigh loop power PAK to increase the loop power from 500 mA to 800 mAUp to 512 zones with Fire Brigade Fire Protection controls and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacement

GBP 661.09
1

Aritech TP-RDR-LRN Truportal Learn-In Reader Multi Frequency - 125KHZ - 13.56MHZ

Aritech 2X-FR-C-99 2X Repeater Panel - Small Cabinet

Aritech 2X-FR-C-99 2X Repeater Panel - Small Cabinet

Aritech 2X-FR-C-99 2X Repeater Panel - Small CabinetThe 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any color and the easy to remove electronics will support in this matter. The gently lined door with the intuitive dark inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial.With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits building owners and life safety system installers alike.The Compact RepeaterThe compact repeater supplied in local language come with a network facillity already assembled no network board required. Except for having no addressable loops and corresponding programmable outputs the setup is similar as a normal fire panel. It has by default 2 conventional relay output 2 supervised inputs 1 RS232 2 USB and 1 Ethernet port. The repeater has no mains voltage power supply unit but it allows for redundant 24VDC supply connections. For future use and expansions there is also already a repeater bus incorporated.The compact repeater is very easy to mount via the DIN-rail mounting option.OptionsThe repeaters use a node on the network similar like a normal panel with a maximum of 32 nodes 32 loops network of fire panels and fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. In case more nodes on the network are required you can expand the network capabilities with an optional panel activation key. For the RS232 connection you can order the 2010-2-232-KIT which includes a RS232 isolator board.Approvals ComplianceCE CPDBS5839-1 compliantWEEE RoHS compliantKey FeaturesLocal or global repeater with or without global control functionalityAuto configuration setup wizards and default EN54 setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dail with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with special paintable synthetic doorEasy removable cover and chassis for quick and clean installationAll pluggable connectors2 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsRedundant 24VDC supply3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsDIN-rail mounting

GBP 538.08
1

Aritech 2X-F1-99 2X Addressable Fire Panel - Large Cabinet - 1 Loop

Aritech 2X-F1-99 2X Addressable Fire Panel - Large Cabinet - 1 Loop

Aritech 2X-F1-99 2X Addressable Fire Panel - Large Cabinet - 1 LoopThe 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any color and the easy to remove electronics will support in this matter. The gently lined door with the intuitive dark inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial.With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits building owners and life safety system installers alike.The panels supports one network board to create a maximum of 32 nodes 32 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 24 zone firefault LED indicator board can be mounted in the panel or repeater with space for a 4 digit number.The fire panels supplied in local language with user interface with 1 loop that supports up to 128 devices in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.Key Features1 loop with up to 512 zones and 300 output groupsUp to 24 LED Zone indicators for Fire and Fault with space for a 4 digit numberAuto configuration setup wizards and default EN54 setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dail with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with special paintable synthetic doorEasy removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 24 hours standby time and 30 minutes alarmCompatible with the new loop powered soundersbeacons and base sounders and the 2000 series detectors with replaceable optical chamber

GBP 533.87
1

Aritech Addressable 1 Loop Fire Panel Small Cabinet 2X-F1-S-99

Aritech Addressable 1 Loop Fire Panel Small Cabinet 2X-F1-S-99

Aritech Addressable 1 Loop Fire Panel Small Cabinet 2X-F1-S-99The 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any color and the easy to remove electronics will support in this matter. The gently lined door with the intuitive dark inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial.With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits building owners and life safety system installers alike.The panels supports one network board to create a maximum of 32 nodes 32 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 24 zone firefault LED indicator board can be mounted in the panel or repeater with space for a 4 digit number.The fire panels supplied in local language with user interface with 1 loop that supports up to 128 devices in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.Key Features1 loop with up to 512 zones and 300 output groupsUp to 24 LED Zone indicators for Fire and Fault with space for a 4 digit numberAuto configuration setup wizards and default EN54 setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dail with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with special paintable synthetic doorEasy removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 24 hours standby time and 30 minutes alarmCompatible with the new loop powered soundersbeacons and base sounders and the 2000 series detectors with replaceable optical chamber

GBP 533.87
1

Aritech 2X-F2-99 2X Addressable Fire Panel - Large Cabinet - 2 Loop

Aritech 2X-F2-99 2X Addressable Fire Panel - Large Cabinet - 2 Loop

Aritech 2X-F2-99 2X Addressable Fire Panel - Large Cabinet - 2 LoopThe 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any color and the easy to remove electronics will support in this matter. The gently lined door with the intuitive dark inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial.With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits building owners and life safety system installers alike.The PanelThe fire panels supplied in local language with user interface with 2 loops that supports up to 256 devices in 512 zones have standard 4 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 256 zones with 4 additional programmable outputs. Add a network board to create a maximum of 32 nodes 32 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Approvals ComplianceCE CPD EN54-2 EN54-4 EN54-21NEN2535 NBNS21-100 compliantBS5839-1 compliantVdS and LPCB certifiedWEEE RoHS compliantKey Features2 loops expandable to 4 with up to 512 zones and 300 outputgroupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dail with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with special paintable synthetic doorEasy removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 72 hours standby time and 30 minutes alarmCompatible with the new loop powered soundersbeacons and base sounders and the 2000 series detectors with replaceable optical chamber

GBP 635.53
1

Aritech 2X-FR-S-99 2X Repeater Panel - Small Cabinet

Aritech 2X-FR-S-99 2X Repeater Panel - Small Cabinet

Aritech 2X-FR-S-99 2X Repeater Panel - Small CabinetThe 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any color and the easy to remove electronics will support in this matter. The gently lined door with the intuitive dark inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial.With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits building owners and life safety system installers alike.The PanelThe fire panel repeaters supplied in local language come with a 2010-2-NB network board already fitted. Except for having no addressable loops and corresponding programmable outputs the setup is similar as a normal fire panel. It and has its own power supply 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe repeaters use a node on the network similar like a normal panel with a maximum of 32 nodes 32 loops network of fire panels and fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 24 zone firefault LED indicator board can be mounted in the panel or repeater with space for a 4 digit number.Approvals ComplianceCE CPD EN54-2 EN54-4 EN54-21NEN2535 NBNS21-100 compliantBS5839-1 compliantVdS and LPCB certifiedWEEE RoHS compliantKey FeaturesLocal or global repeater with or without global control functionalityUp to 24 LED Zone indicators for Fire and Fault with space for a 4 digit numberAuto configuration setup wizards and default EN54 setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dail with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with special paintable synthetic doorEasy removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 24 hours standby time and 30 minutes alarmComes standard fitted with network board

GBP 686.39
1

Aritech 2X-FR-99 2X Repeater Panel - Large Cabinet

Aritech 2X-FR-99 2X Repeater Panel - Large Cabinet

Aritech 2X-FR-99 2X Repeater Panel - Large CabinetThe 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any color and the easy to remove electronics will support in this matter. The gently lined door with the intuitive blue inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial.With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits building owners and life safety system installers alike.The PanelThe fire panel repeaters supplied in local language come with a 2010-2-NB network board already fitted. Except for having no addressable loops and corresponding programmable outputs the setup is similar as a normal fire panel. It and has its own power supply 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe repeaters use a node on the network similar like a normal panel with a maximum of 32 nodes 32 loops network of fire panels and fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for textApprovals and ComplianceCE CPD EN54-2 EN54-4 EN54-21NEN2535 NBNS21-100 compliantBS5839-1 compliantVdS and LPCB certifiedWEEE RoHS compliantKey FeaturesLocal or global repeater with or without global control functionalityUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default EN54 setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dail with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with special paintable synthetic doorEasy removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 72 hours standby time and 30 minutes alarmComes standard fitted with network board

GBP 686.39
1

Aritech 2X-F2-PRT-99 2X Addressable Fire Panel - Large Cabinet with Integral Printer - 2 Loop

Aritech 2X-F2-PRT-99 2X Addressable Fire Panel - Large Cabinet with Integral Printer - 2 Loop

Aritech 2X-F2-PRT-99 2X Addressable Fire Panel - Large Cabinet with Integral Printer - 2 LoopThe 2X Series life safety control systems are bringing the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. They feature an attractive contemporary design that fits with any decor. Special plastics allows for painting in any color and the easy to remove electronics will support in this matter. The gently lined door with the intuitive dark inset user interface and EN54 compliant graphical LCD offers a distinctive flair. The main controls are clearly but discreetly highlighted with the focus on the central located Jog Dial. With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits building owners and life safety system installers alike.The PanelThe fire panels supplied in local language with user interface with 2 loops that supports up to 256 devices in 512 zones have standard 4 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available. The build-in printer allows for printing live panel events or reports.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 32 nodes 32 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Approvals ComplianceCE CPD EN54-2 EN54-4 EN54-21NEN2535 NBNS21-100 compliantBS5839-1 compliantVdS and LPCB certifiedWEEE RoHS compliantKey FeaturesBuild-in thermal printer with paper replacement from the front2 loops expandable to 4 with up to 512 zones and 300 outputgroupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dail with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with special paintable synthetic doorEasy removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 72 hours standby time and 30 minutes alarmCompatible with the new loop powered soundersbeacons and base sounders and the 2000 series detectors with replaceable optical chamber

GBP 946.54
1

Aritech DP991 990 Series Discovery Optical Detector

Aritech DP991 990 Series Discovery Optical Detector

Aritech DP991 990 Series Discovery Optical DetectorThe DP991 is an elegant slim-line optical sensor with high performance analogue addressable features. Compensation for sensor drift is included as part of the internal signal-processing algorithm.Optical Smoke MonitorThe optical smoke detector has an internal pulsing LED and a photo-diode at an obtuse angle. In clear air conditions the photo-diode in the monitor receives no light from the LED and produces a corresponding analogue signal. This signal increases when smoke enters the chamber and light is scattered onto the photodiode. The signal is processed by the electronic circuitry and transmitted to the control equipment in exactly the same way as in the case of the ionisation smoke monitor.Drift CompensationThe drift compensation algorithm will compensate for changes in sensor output caused for example by dust in the chamber and will therefore hold the sensitivity at a constant level even with severe chamber contamination. This increased stability is achieved without significantly affecting the detectors sensitivity to fire.Compensation values are stored in non-volatile memory and will be retained even if detectors are disconnected.Unique AddressingA unique patented addressing method provides simple user-friendly and accurate identification of monitor location whereby a coded card inserted in the base is read by any monitor as it is plugged in. All the electronic components are in the monitor but the location information is held in the base. Addressing errors during maintenance and service are eliminated. Pre-coded and pre-numbered address cards are also available. These address cards simplify and speed up installation and commissioning.Key Features5 Approved response modes for ease of optimisation to different environmentsRejection of transient signalsDrift compensation to ensure constant sensitivity360 Alarm visibilityFlashing LED optionFast alarm reportingEN54 approved and CPR certified

GBP 54.12
1