28 results (0,14713 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Orbis TimeSaver Diode Base - ORB-DB-00003-APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201The Series 65 Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the L1 IN and L1 OUT wiring terminals.This base can only be used with compatible control equipment.OperationAll detectors in the Series 65 range fit into Series 60 standard mounting bases. The bases are of 100mm diameter and have five terminals marked according to their function Line 1 in line 1 out line 2 in and out remote indicator negative earth. Detectors are polarity insensitive so that identification of positive and negative lines is only required if a remote LED is fitted. An earth connection is not required for either safety or correct operation of detectors.The earth terminal is provided for tidy termination of earthed conductors or cable screens and to maintain earth continuity where necessary. Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws at a spacing of 51 to 69mm. Detectors fit into bases one way only and require clockwise rotation without push force to be plugged in.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connectorContinues to work during unauthorised removal of detectorsBrand FeaturesWide-operating voltage of 933 V DCWide-operating and storage temperature of -20C to 60CCan be used on security systemsElectrically and mechanically compatible with Series 60Proven detection performance

GBP 2.60
1

Apollo SA5000-202APO XPERT 8 Intelligent Mounting Base - Red

Apollo Singular Transparent Hinged Cover for Apollo Call Point 44251-189APO

Apollo Series 65 Standard Base - 45681-200APO

Apollo Orbis BR I.S. Heat Detector ORB-HT-51149-APO

Apollo Soteria XPERT 8 Intelligent Mounting Base SA5000-200APO

Apollo Soteria XPERT 8 Intelligent Mounting Base SA5000-200APO

Apollo Soteria XPERT 8 Intelligent Mounting Base SA5000-200APOAll detectors in the Soteria XP95 and Discovery range fit into the XPERT 8 Intelligent Mounting Base.The base has a wide interior diameter for ease of access to cables and terminals. The E-Z Fit feature allows you to fit the base screws place the XPERT 8 Intelligent Mounting Base over the screws slide it into place and tighten the screws.The detector requires a clockwise rotation into the base for fitting. Additionally the detector can be locked into the base for increased security by a grub-screw using a 1.5mm hexagonal driver.The XPERT 8 card part number 38532-064 supplied with the base has pre-punched pips to remove to set the address. Refer to the Coding Guide for details on how to set the address.Backwards CompatibilitySoteria detectors have been designed to operate on XP95 and Discovery loops. This allows for Soteria detectors and bases to operate on existing systems and for Soteria detectors to operate on XP95 and Discovery bases XPERT 7 Intelligent Mounting Base. It should be noted that not all features of Soteria will be available when used with XP95 or Discovery fire control panels. If Soteria detectors are used with XP95 fire control panels incorporating drift compensation algorithms these must be disabled when communicating with Soteria devices.When Soteria detectors are used with an XPERT 7 Intelligent Mounting Base on a CoreProtocol system Soteria devices will have a 128 address offset due to only 7 address pips being available on the XPERT 7 card. For example an XPERT 7 card set at 32 will address as 160 on CoreProtocol with Soteria detectors.Key FeaturesCompatibility with Soteria XP95 and Discovery detectorsIsolated and Non-isolated devices supportedIsolated wiper - maintains loop connectivity during temporary removal of devicesXPERT 8 card for Core-ProtocolE-Z Fit allows for simple mounting of the detector base after wiringKeyed to accept only addressable devicesBase mark allows for LED detector alignmentPlease Note XPERT 8 card increase the address capacity to 254 when using Soteria detector and Core-Protocol enabled fire control panel.

GBP 2.64
1

Apollo 29600-799 Talentum Test Torch

Apollo XP95 EN54 Glass Replacement 26729-154

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Mounting Base - 45681-210APOAll detectors in the Discovery range fit the IntelligentMounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.Universal address cards known as XPERT cards are supplied with all bases. Consult the coding guide in the installation instructions to determine which pips are to be removed from the card to give the correct address.Lay the card on a flat surface pips down insert a screwdriver into the slot on the reverse of the pip to be removed and give a firm twist. When the card is coded insert it into the slot in the side of the appropriate base making sure that the card locks itself into place. As a detector is inserted into the base the remaining pips operate the address buttons on the detector and the detector electronics reads the address.OperatingAn earth connection is not required for either safety or correct operation of detectors. The ground earth terminal is isolated and is provided for tidy termination of grounded conductors or cable screens and to maintain earth continuity where necessary. All terminals are marked according to their function.Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws. The slots enable two fixing screws to be located at a spacing of 51mm to 69mm. Detectors fit into bases one way only without snagging and require clockwise rotation without push force to be plugged in.Key Features XPERT AddressingOne way fit of detectorLocking feature to prevent unauthorised detector removal

GBP 2.50
1

Apollo AlarmSense Sounder Beacon Base 45681-509APO

Apollo AlarmSense Base 45681-244APO

Apollo Series 65 Marine Mounting Base 45681-200MAR

Apollo AlarmSense Sounder Base 45681-510APO

Apollo AlarmSense Sounder Base 45681-510APO

Apollo AlarmSense Sounder Base 45681-510APOThe AlarmSense Sounder Base can only be used with AlarmSense systems. It is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and red or white capsare available for stand-alone installation.Brand InformationAlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive.AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation.As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extendKey FeaturesAlarmSense prioritynon priority signal recognitionDetects the removal of a detector head and reports a faultContinues to work during unauthorised removal of detectorsQuick and simple installationProvides audible signal and detection at one pointHigh and low volume ranges

GBP 22.99
1

Apollo XP95 Discovery Isolator Base 45681-211APO

Apollo XP95 Mini Switch Monitor - 55000-760APO

Apollo Waterproof Addressable Manual Call Point 58200-951APO

Apollo Marine Mini Switch Monitor 55000-775MAR

Apollo Intelligent White Manual Call Point - SA5900-903APO

Apollo Intelligent White Manual Call Point - SA5900-903APO

Apollo Intelligent White Manual Call Point - SA5900-903APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Intelligent Blue Manual Call Point - SA5900-905APO

Apollo Intelligent Blue Manual Call Point - SA5900-905APO

Apollo Intelligent Blue Manual Call Point - SA5900-905APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Intelligent Orange Manual Call Point - SA5900-907APO

Apollo Intelligent Orange Manual Call Point - SA5900-907APO

Apollo Intelligent Orange Manual Call Point - SA5900-907APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 47.57
1