25 results (0,13622 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Loop-Powered Clear Visual Indicator 55000-878APO

Apollo Intelligent Open-Area Clear Beacon - 55000-010APO

Apollo Discovery Clear Open-Area Sounder Beacon - 58000-007APO

Apollo Intelligent Clear Open-Area Sounder Beacon - 55000-006APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring.The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesWirelessBi-directional monitored radio platformChoice of 32 selectable tonesAudible self-test availableOutput is between 92 and 106dbA at 1m dependent on tone setting

GBP 372.43
1

Apollo Intelligent Red Open-Area Sounder Beacon - 55000-005APO

Apollo Discovery Red Open-Area Voice Sounder - 58000-010APO

Apollo Discovery Red Open-Area Voice Sounder Beacon - 58000-030APO

Apollo MiniDisc Remote Indicator 53832-070APO

Apollo Series 65 Optical Smoke Detector - 55000-317APO

Apollo Discovery White Open-Area Voice Sounder - 58000-020APO

Apollo XP95 Optical Smoke Detector Black - 55000-660APO

Apollo Orbis TimeSaver Sav-Wire Base ORB-SW-10005-APO

Apollo Orbis TimeSaver Base - ORB-MB-00001-APO

Apollo Discovery White Open-Area Voice Sounder Beacon - 58000-040APO

Apollo Orbis TimeSaver Deep Base - ORB-MB-00019-APO

Apollo Orbis TimeSaver Relay Base - ORB-RB-10004-APO

Apollo Marine Mini Switch Monitor 55000-775MAR

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1

Apollo Series 65 Optical Smoke Detector with Flashing LED 55000-316APO

Apollo Series 65 Optical Smoke Detector with Flashing LED 55000-316APO

Apollo Series 65 Optical Smoke Detector with Flashing LED 55000-316APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light.The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode.If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate.To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation.The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 16.52
1

Apollo Discovery Optical Smoke Detector 58000-600APO

Apollo Discovery Optical Smoke Detector 58000-600APO

Apollo Discovery Optical Smoke Detector 58000-600APOThe Discovery Optical Smoke Detector operates using the light scatter principle and is ideal for applications where slow-burning or smouldering fires pose a potential risk. Discovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms. Drift compensation further reduces the likelihood of false alarms caused by a build-up of dust in the sensing chamber.OperationThe Discovery Optical Detector has a white moulded polycarbonate case with wind-resistant smoke inlets. The two indicator LEDs are red in alarm. Within the case is a printed circuit board which on one side has the light-proof chamber with integral gauze surrounding the optical measuring system and on the other the signal processing and communications electronics. An infra-red light emitting diode within its collimator is arranged at an obtuse angle to the photo-diode. The photo-diode has an integral daylight-blocking filter.The IR LED emits a burst of collimated light every second. In clear air the photo-diode receives no light directly from the IR LED because of the angular arrangement and the chamber baffles. When smoke enters the chamber it scatters light from the emitter IR LED onto the photo-diode in an amount related to the smoke characteristics and density. The photo-diode signal is processed to provide an analogue value for transmission when the detector is interrogated.Key FeaturesResponds well to slowburning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFive response modesRemote test feature

GBP 40.98
1

Apollo Discovery Marine Optical Smoke Detector 58000-600MAR

Apollo Discovery Marine Optical Smoke Detector 58000-600MAR

Apollo Discovery Marine Optical Smoke Detector 58000-600MARThe Discovery Marine Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.Operating PrinciplesThe Discovery Marine Optical Smoke Detector has a white moulded polycarbonate case with wind-resistant smoke inlets.The indicator LEDs are colourless when the detector is in quiescent state and red in alarm. Within the case is a printed circuit board which on one side has the light-proof chamber with integral gauze surrounding the optical measuring system and on the other the signal processing and communications electronics.An infra-red light emitting diode within its collimator is arranged at an obtuse angle to the photo-diode. The photo-diode has an integral daylight-blocking filter.The IR LED emits a burst of collimated light every second.In clear air the photo-diode receives no light directly from the IR LED because of the angular arrangement and the chamber baffles. When smoke enters the chamber it scatters light from the emitter IR LED onto the photo-diode in an amount related to the smoke characteristics and density. The photo-diode signal is processed to provide an analogue value for transmission when the detector is interrogated.Maintenance ServiceDetectors should be maintained according to BS 5839-1 or other locally applicable code. Test Equipment can be ordered from us which can test smoke and heat detectors. Detectors should not be cleaned in the field except for careful removal of exterior dirt with a damp cloth.Key FeaturesResponds well to slow-burning smouldering firesSuitable for bedrooms and escape routesUnaffected by wind or atmospheric pressureRemote test featureRejection of transient signals

GBP 59.16
1

Apollo Orbis Optical Smoke Detector - ORB-OP-12001-APO

Apollo Orbis Optical Smoke Detector - ORB-OP-12001-APO

Apollo Orbis Optical Smoke Detector - ORB-OP-12001-APOThe Orbis Optical Smoke Detector operates on the well-established light scatter principle. The sensing technology used is radically different from previous optical detectors and significantly reduces false alarms. Orbis operates on the well-established light scatter principle. The remarkable optical design of the Orbis optical smoke detector allows it to respond to a wide spectrum of fires. The sensing chamber of the Orbis optical smoke detector contains an optical sensor which measures back-scattered light as well as the more usual forward-scattered light.Sensitivity to black smoke is greatly improved. The detector is calibrated so that Orbis is highly reliable in detecting fires but is much less likely to generate false alarms than earlier smoke detectors. The stability of the detectorhigh reliability low false alarm rateis further increased by the use of algorithms to decide when the detector should change to the alarm state. This removes the likelihood of a detector producing an alarm as a result of smoke from smoking materials or from another non-fire source.Brand InformationOrbis is a range of conventional detectors which has been developed and tested to create advantages for fire engineers and installers as well as owners and users of buildings. Orbis is a range with modern styling and a mounting base that saves installation time. It is electrically compatible with Apollo Series 65 and previous ranges of conventional detector.Orbis is a demonstration of Apollos commitment to the market for high quality conventional detectors for use in small to medium size installations. In developing this range Apollo has put ease of installation and reliability in daily operation at the forefront of considerations. The attractive and compact design means that Orbis will blend in well with all architectural styles.Key FeaturesResponds well to slow burning smouldering firesTransient rejection algorithms reduce false alarmsAutomatic drift compensation with DirtAlert a yellow flashing LED to easily identify dirty detectorsRed flashing LED at StartUp confirms the device is operatingSensAlert yellow flashing LED indicates faulty operationFasTest takes just four seconds to test and confirm detectors are functioning correctlyDustDefy system prevents dust ingress while maintaining airflow

GBP 17.24
1

Apollo Intelligent Auto-Aligning Beam Detector SA7100-100APO

Apollo Intelligent Auto-Aligning Beam Detector SA7100-100APO

Apollo Intelligent Auto-Aligning Beam Detector SA7100-100APOThe Intelligent Auto-Aligning Beam Detector combines a transmitterreceiver in the same detector head with an automatic alignment motor. This combination with integrated addressability allows for quick and simple installation. The Intelligent Auto-Aligning Beam Detector automatically compensates for environmental effects on the beam signal keeping the unit in the best possible working order. This is achieved through the combination of software automatic gain control and motorised realignment of the beam.OperationThe Intelligent Auto-Aligning Beam Detector is a compact detector for detecting smoke in large open areas such as warehouses theatres churches and sports centres. It comprises a ground level loop-powered controller a detector head with an operating range of 8m-50m and a single prism. The operating range of each detector head can be increased up to 100m by using the Extension Kit which comprises of three additional prisms.An additional detector head can be connected to the controller. Each head has a loop address. It also has a built in 20T negative bi-directional short circuit isolator and it is compatible with control panels using CoreProtocol Discovery and XP95 protocol. A built-in laser provides rapid initial alignment and thereafter the detector head will continuously automatically align and compensate for any building movement.The status of each detector can be monitored through the controller which is sited at ground level. The detector head operates both as a transmitter and a receiver. A well-defined IR beam is projected to a prism mounted on the opposite wall which is reflected back to the receiver. In the event of smoke partially obscuring the light an imbalance between the transmitted and received light will occur. The detector will then transmit an alarm value to the control panel.The detector is factory set to a beam obscuration of 35 which is the best setting for most factories and warehouses. The setting can be changed to 25 for offices and clean areas such as theatres or to 50 for hostile areas such as mills or foundries. The detector reports a pre-alarm analogue value 48 at approximately 75 of the alarm threshold. The detector compensates automatically for gradual contamination of the lenses in order to avoid false alarms. The detector is non-latching and resets 30 seconds after an alarm event ceases and in 3 seconds after the removal of a fault.Key FeaturesLoop Powered and compatible with XP95 Discovery and CoreProtocolIncorporates a bi directional short-circuit isolatorAutomatic drift compensationAutomatic resetGround level ControllerAutomatic alignment compensation for building movementLaser assisted alignment for quick installationAllows for 2 detector heads per controllerUp to 100m rangePre-alarm thresholdEN 54-12 and EN 54-17 certified

GBP 599.51
1