10 results (0,13950 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo XPander CS Heat Detector XPA-HT-11171-APO

Apollo XPA-CB-14027-APO XPander Multisensor Detector with Sounder VID Base White Flash

Apollo XPA-CB-14023-APO XPander Multisensor Detector with Sounder VID Base Red Flash

Apollo XPA-CB-14019-APO XPander Multisensor Detector with Sounder Base

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke DetectorXPA-CB-14020-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectors remote test facility3-5 years battery life

GBP 370.69
1

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring.The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesWirelessBi-directional monitored radio platformChoice of 32 selectable tonesAudible self-test availableOutput is between 92 and 106dbA at 1m dependent on tone setting

GBP 372.43
1

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat DetectorXPA-CB-14022-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander Red Sounder with Mounting Base - XPA-CB-14001-APO

Apollo XPander Red Sounder with Mounting Base - XPA-CB-14001-APO

Apollo XPander Red Sounder with Mounting Base - XPA-CB-14001-APOThe XPander Sounder and Sounder Base is a wireless and designed to be used with XPander detectors and manual call points.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Features WirelessBi-directional monitored radio platformChoice of 32 selectable tonesAudible self-test availableOutput is between 92 and 106dBA at 1m - dependent on tone setting

GBP 237.64
1

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat DetectorXPA-CB-14021-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APO

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APO

Apollo XPander White Sounder with Mounting Base XPA-CB-14002-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 240.92
1