6 results (0,11952 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Advanced QZ-4 QuickZone 4 Zone Conventional Control Panel

Advanced QZ-4 QuickZone 4 Zone Conventional Control Panel

Advanced QuickZone 4 Zone Conventional Control Panel - QZ-4QuickZone is a 2 or 4 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is ways to install maintain and is simple to operate for the end user. Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System or General. As well as this the panel is capable of indicating zones in Fire Fault and disablements. Auxiliary Output and Sounder status will be shown including if the panel is in test mode. Controls enabled in Level 2 include Resound Silence and Reset.Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set.Key Features2 or 4 zoneTwin Wire selection by DIL switchApproved to EN54-2 43 year warranty as standardSimple colour coded buttons for controls and programmingIntegral 1 amp switch mode PSUClass change alert inputsFire fault relays2 monitored sounder circuitsTest modeSpace for up to 3.2Ah batteriesKey-switch or code entry for activation of controls

GBP 335.18
1

Advanced QZ-2 QuickZone 2 Zone Conventional Control Panel

Advanced QZ-2 QuickZone 2 Zone Conventional Control Panel

Advanced QuickZone 2 Zone Conventional Control Panel - QZ-2QuickZone is a 2 or 4 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is ways to install maintain and is simple to operate for the end user. Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System or General. As well as this the panel is capable of indicating zones in Fire Fault and disablements. Auxiliary Output and Sounder status will be shown including if the panel is in test mode. Controls enabled in Level 2 include Resound Silence and Reset.Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set.Key Features2 or 4 zoneTwin Wire selection by DIL switchApproved to EN54-2 43 year warranty as standardSimple colour coded buttons for controls and programmingIntegral 1 amp switch mode PSUClass change alert inputsFire fault relays2 monitored sounder circuitsTest modeSpace for up to 3.2Ah batteriesKey-switch or code entry for activation of controls

GBP 284.90
1

Advanced QuickZone XL 4 Zone Conventional Control Panel - QZXL-4

Advanced QuickZone XL 4 Zone Conventional Control Panel - QZXL-4

Advanced QuickZone XL 4 Zone Conventional Control Panel - QZXL-4QuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater. As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode.Controls enabled in Level 2 include Resound Silence and Reset. Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key Features4 to 12 ZonesTwin Wire selection by DIL switchFully approved to EN54-2 4Three year warranty as standardIntegral 3 Amp switch mode PSUClass Change Alert programmable inputsProgrammable relays and outputsTest Mode with or without soundersAlarm load of 2.4A shared across all sounder outputsModular expansion zone cards available2 Additional sounder circuits with high spec expansion cardFully functional repeater panelsCan support up to 8 repeater panelsKey-switch or code entry for activation of controlsSpace for up to 7.0Ah batteriesTwo monitored sounder circuits fitted as standardIntegral detector removal monitoring

GBP 473.83
1

Advanced QZXL-12HS QuickZone 12 Zone Control Panel with 2x Sounder Circuits and Switched Relay

Advanced QZXL-12HS QuickZone 12 Zone Control Panel with 2x Sounder Circuits and Switched Relay

Advanced QZXL-12HS QuickZone 12 Zone Control Panel with 2x Sounder Circuits and Switched RelayQuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater. As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode.Controls enabled in Level 2 include Resound Silence and Reset. Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key Features4 to 12 ZonesTwin Wire selection by DIL switchFully approved to EN54-2 4Three year warranty as standardIntegral 3 Amp switch mode PSUClass Change Alert programmable inputsProgrammable relays and outputsTest Mode with or without soundersAlarm load of 2.4A shared across all sounder outputsModular expansion zone cards available2 Additional sounder circuits with high spec expansion cardFully functional repeater panelsCan support up to 8 repeater panelsKey-switch or code entry for activation of controlsSpace for up to 7.0Ah batteriesTwo monitored sounder circuits fitted as standardIntegral detector removal monitoring

GBP 799.87
1

Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay

Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay

Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay -QZXL-8HSQuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater. As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode.Controls enabled in Level 2 include Resound Silence and Reset. Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key Features4 to 12 ZonesTwin Wire selection by DIL switchFully approved to EN54-2 4Three year warranty as standardIntegral 3 Amp switch mode PSUClass Change Alert programmable inputsProgrammable relays and outputsTest Mode with or without soundersAlarm load of 2.4A shared across all sounder outputsModular expansion zone cards available2 Additional sounder circuits with high spec expansion cardFully functional repeater panelsCan support up to 8 repeater panelsKey-switch or code entry for activation of controlsSpace for up to 7.0Ah batteriesTwo monitored sounder circuits fitted as standardIntegral detector removal monitoring

GBP 636.84
1

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High Spec

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High Spec

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High SpecQuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries.The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits.Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode.Dependency modes A B C available. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater.As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode. Controls enabled in Level 2 include Resound Silence and Reset.Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Panel wide settings including access codes and delays. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key FeaturesIntegral detector removal monitoringTwo monitored sounder circuits fitted as standardSpace for up to 2 x 7.0Ah batteriesKey-switch or code entry for activation of controlsCan support up to 8 fully functional repeater panels2 Additional sounder circuits with high spec expansion cardModular expansion zone cards availableAlarm load of 2.4A shared across all sounder outputsTest Mode with or without soundersProgrammable relays and outputsClass Change Alert programmable inputsIntegral 3 Amp switch mode PSUThree-year warranty as standardFully approved to EN54-2 44 to 12 Zones4 x conventional or Twin Wire zone circuits2 x switched ve outputs1 x Aux relay output2 x monitored sounder circuits

GBP 220.18
1