52 results (0,15763 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

RGL Electronics ML600-D-MDS Monitored Double Slimline Mini Magnet - 600 lbs 280 kg Holding Force

RGL Electronics ML1200-D-MDS Double Monitored Magnet Offering 1200 lbs 545 kg x 2 Holding Force

Notifier Honeywell 15 Watt Horn Loudspeaker 582479

RGL Electronics ML1200-D-M Double Monitored Magnet Offering 1200 lbs 545 kg x 2 Holding Force

Cooper Fulleon 1380-15-D Floor amp Wall Mount Electromagnetic Door Release - 100KG -24V

Cooper Fulleon 1370-15-D Floor amp Wall Mount Electromagnetic Door Release 50kg 24v 15cm Bracket

Kentec K1821-15 Sigma A SI Extinguishant Status Unit - 6 Lamp Manual Release - Red

Kentec K1821-15 Sigma A SI Extinguishant Status Unit - 6 Lamp Manual Release - Red

Kentec K1821-15 Sigma A SI Extinguishant Status Unit - 6 Lamp Manual Release - RedThe Sigma A-Si range of status indicators provides detailed status information for Sigma A-XT releasing control equipment.All models provide high brightness LED indication of Manual Only Automatic and Manual Abort Operated Disabled Imminent and Released conditions. Models are also available with zonal fire indicators and a common trouble indicator.For systems where local control of the AutomaticManual mode and or a Manual extinguishant release control are required units are available with these controls fitted. All models have supervised inputs for the remote connection of AutomaticManual mode and abort switches.All units contain a large LED display that shows a countdown of the time remaining until release in seconds.Up to seven Sigma A-SI status units can be connected to the Sigma A-XT serial bus and require just two cores for data and two cores for power. Once connected status units are supervised and the Sigma A-XT control panel will indicate a trouble condition should any unit become disconnected.Key FeaturesHigh brightness LEDsDetailed indication of the status of the Control PanelSupervised data connectionCountdown shows time remaining until releaseManual only and Automatic Manual mode selectFour-wire connection data and powerProtected dual action manual release switch optionOption for zonal fire and trouble indication with buzzerRobust high quality enclosureEasy access to terminalsRemote AutoManual door interlock input supervisedRemote Abort input supervisedInternal trouble diagnosis indicators

GBP 158.54
1

Aritech DB992IVAS 990 Series Mounting Base w SounderVisual Indicator and Isolator

Aritech DB992IVAS 990 Series Mounting Base w SounderVisual Indicator and Isolator

Aritech DB992IVAS 990 Series Mounting Base with SounderVisual Indicator and IsolatorThe DB992IVAS sounder beacon base is a multifunctional device comprising of a mounting base for Series 990 fire detectors a sounder a beacon and a short circuit isolator. It is used to provide audible and visual warning of a fire alarm in an enclosed area. The DB992IVAS may be used either with a detector fitted or with a cap for operation as a stand-alone alarm device.Tone and Volume SelectionThe DB992IVAS offers a choice of 15 evacuation and 15 alert tones. Two tones may be selected during installation one for evacuation and one for alert. Volume levels may be selected during commissioning to one of 7 pre-set levels with output ranging from 60 dBA to 90 dBA. The low volume range is useful in areas such as hospitals where the alert is initially intended to warn staff only.During commissioning the sounder volume can be adjusted on location without disassembly or removal. With the CIE in setup mode the commissioning engineer is able to adjust the volume using a magnetic wand. Once all sounders have been adjusted setup mode on the CIE is cancelled and all sounder volume levels are stored in the sounder.Group Addressing and ControlWhen multiple sounderbeacons in an area always need to be activated simultaneously the DB992IVAS group addressing can be stored in each device allowing the CIE to activate the group with a single command.The installation also has free selection from the CIE on use of sounder only beacon only or combined sounderbeacon operation. Functionality can be changed during time schedules or time delays as is required per individual location.Key FeaturesSupports 15 evacuation and 15 alert tones7 Volume levelsIndividual or software defined group addressingIndependent sounder and beacon controlSet-up and testing at point on installationBuilt in isolator with status informationApollo equivalent 45681-338

GBP 119.68
1

Notifier BRH-PC-I02 High Performance Detector Base Sounder Strobe NFXI-BSF-WCH

Apollo Discovery Red Open-Area Voice Sounder Beacon - 58000-030APO

Apollo Discovery Red Open-Area Voice Sounder - 58000-010APO

Aritech ATS1740 Data Bus IsolatorRepeater - Expands Data Bus By 1.5km

Haes Lockdown Alert Alarm Relay

Haes PSM5-27 Power Supply Module - 5A 27V

Aritech TVP-PME-01 TruVision Multi Imager And PM Series IP PTZ Extendable Pendant Mount Bracket

C-Tec BF447ACXDR Addressable Wall Voice Sounder VAD with Deep Base

C-Tec NC943B Conventional Single Zone Call Controller

C-Tec BF447ACXSR Addressable Wall Voice Sounder VAD with Shallow Base

Apollo Discovery White Open-Area Voice Sounder - 58000-020APO

STI AP-3-R-B Alert Point Beacon Red - Fire Label

STI AP-3-R-X Alert Point Beacon Red - Custom Marking

STI AP-3-R-A Alert Point Beacon Red House Flame Logo

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone InterfaceThe A70E-2 zone interface is fully loop powered and enables existing or new conventional zones to be interfaced to an analogue system allowing all areas of a site to be controlled by the ZP analogue panel. Through its interface each zone is assigned a unique address. Zones are monitored for fire and fault conditions and status is reported to the ZP control panel every 2 seconds. Zones of up to 15 Ziton Z600 conventional trigger devices can be connected to the interface with a maximum of 127 interface units installed on each ZP loop.The A70E monitors its conventional zone wiring for open and short circuit faults via end of line resistors supplied with the unit. When detectors are installed with Z6-BS5 bases the interface maintains complete operation of all other zone devices should a detector from within the zone be emoved from its base. Clear visual indication is shown on the front of the A70E moulding for alarm red LED and fault amber LED.Deriving power directly from the loop wiring and with a low current consumption in addition to zonal connection the interface has many system applications ranging from the interface of equipment for hazardous areas to the operation of magnetic door retainers via an interposing relay and linear beam detectors. Housed in low profile mouldings the interface is designed to clip directly onto a standard DIN35 rail fixing or be installed in a SMB-DIN100 box one unit capacity or a SMB-DIN200 box two unit capacity. In systems where numerous interfaces are installed or current requirement is excessive the A70E can be powered from an external power supply.Key FeaturesInterfaces up to 15 Ziton Z600 conventional devices to the ZP loopAddressable - reports status every 2 secondsMonitors conventional zone wiringDetector removal monitoring with Z6-BS5 basesDIN35 rail mountedUp to 127 conventional zones interfaced to each ZP loop with external PSU

GBP 114.34
1