5 resultater (0,22637 sekunder)

Mærke

Butik

Pris (EUR)

Nulstil filter

Produkter
Fra
Butikker

GEN ENERGY Batteri G-B100/98W 98Wh/ 6.8Ah 12A Batteri

GEN ENERGY Batteri G-B100/98W 98Wh/ 6.8Ah 12A Batteri

G-B100/98W 12A V-MOUNT BATTERY CHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Charge the battery to full before first use. When you charge this battery, Battery capacity LED gauge button will turn on indicating the capacity being charged. Lithium ion batteries have a slight self discharge, therefore it is recommended to charge prior to use. DISCHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Camera's low voltage alarm is recommended to set 13~13.5V Battery will stop at 12V to extend its life.* Microwave transmitters with 5W outputs or over should be kept as far away from the battery. It may disrupt or stop supplying power. Be sure to remove the battery from the device after use. If so, it will consume large standby power and over-discharge protection may be activated. USB is activated by pushing Battery capacity LED gauge button. USB power will turn on automatically 30 minute after no use. Battery run time reduces when it is working below or above the recommended temperature range. SPECIFICATION TYPE V-MOUNT BATTERY Cell chemistry Li-ion Norminal voltage DC 14.4V Capacity 6.8h Charge voltage 16.8V Charge current Max. 3.5A Max. discharge rate 12A D-Tap Output norminal voltage : 14.4V Max. load :7A USB Output voltage : DC 5.0V Max. load : 2.3A Auto power off : 30 minutes after no use End voltage 12V Battery protection circuit Over-charge, Over-discharge, Over-current ( Cell and Pack separately), Over-temperature, Reverse charge Ambient temperature To charge : 10°C ~ 30°C (32°F ~ 104°F recommended) To discharge : -20°C ~ 50°C ( -4°F ~ 122°F), 10°C ~ 40°C (50°F ~104°F recommended) To store : `-20°C ~ 40°C (-4°F ~ 104°F) (<85% RH) (less than 1 month) Dimension 97(W) x 146(H) x 39(D)mm 3.82(W) x 5.75(H) x1.54(D)" Weight approx.620g / 1.36lbs EAN kode: 7311920026500 Type: Batterier

DKK 1499.00
1

GEN ENERGY Batteri G-B100/160W 160Wh/ 11Ah 12A Batteri

GEN ENERGY Batteri G-B100/160W 160Wh/ 11Ah 12A Batteri

G-B100/160W 12A V-MOUNT BATTERY CHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Charge the battery to full before first use. When you charge this battery, Battery capacity LED gauge button will turn on indicating the capacity being charged. Lithium ion batteries have a slight self discharge, therefore it is recommended to charge prior to use. DISCHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Camera's low voltage alarm is recommended to set 13~13.5V Battery will stop at 12V to extend its life.* Microwave transmitters with 5W outputs or over should be kept as far away from the battery. It may disrupt or stop supplying power. Be sure to remove the battery from the device after use. If so, it will consume large standby power and over-discharge protection may be activated. USB is activated by pushing Battery capacity LED gauge button. USB power will turn on automatically 30 minute after no use. Battery run time reduces when it is working below or above the recommended temperature range. SPECIFICATION TYPE V-MOUNT BATTERY Cell chemistry Li-ion Norminal voltage DC 14.4V Capacity 11Ah Charge voltage 16.8V Charge current Max. 6A Max. discharge rate 12A D-Tap Output norminal voltage : 14.4V Max. load :7A USB Output voltage : DC 5.0V Max. load : 2.3A Auto power off : 30 minutes after no use End voltage 12V Battery protection circuit Over-charge, Over-discharge, Over-current ( Cell and Pack separately), Over-temperature, Reverse charge Ambient temperature To charge : 10°C ~ 30°C (32°F ~ 104°F recommended) To discharge : -20°C ~ 50°C ( -4°F ~ 122°F), 10°C ~ 40°C (50°F ~104°F recommended) To store : `-20°C ~ 40°C (-4°F ~ 104°F) (<85% RH) (less than 1 month) Dimension 97(W) x 146(H) x 59(D)mm 3.82(W) x 5.75(H) x2.32(D)" Weight approx. 1070g / 2.35lbs EAN kode: 7311920026517 Type: Batterier

DKK 1879.95
1

GEN ENERGY Batteri G-B100/390W 390Wh/ 27Ah 312W Batteri

GEN ENERGY Batteri G-B100/390W 390Wh/ 27Ah 312W Batteri

G-B100/390W 26A V-MOUNT BATTERY (390Wh) This battery has 26A Min. 312W, the biggest power in the world, which was born for ALEXA LF and Skypanel S60 full power working solution. You can use only 1 pc of 14.4V battery for ALEXA LF and 2 pcs of batteries for Skypanel S60. G-P26F plate is needed for ALEXA LF with this 1 battery. G-PB48 power bank is needed for Skypanel S60 with these 2 batteries. Shock-proof, Short-proof, Lowest impedance. CHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Charge the battery to full before first use. When you charge this battery, Battery capacity LED gauge button will turn on indicating the capacity being charged. Lithium ion batteries have a slight self discharge, therefore it is recommended to charge prior to use. DISCHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Camera's low voltage alarm is recommended to set 13V. Battery will stop at 12V to extend its life. * Microwave transmitters with 5W outputs or over should be kept as far away from the battery. It may disrupt or stop supplying power. Be sure to remove the battery from the device after use. If so, it will consume large standby power and over-discharge protection may be activated. USB is activated by pushing Battery capacity LED gauge button. USB power will turn on automatically 30 minute after no use. Battery run time reduces when it is working below or above the recommended temperature range. Specifications: TYPE V-MOUNT BATTERY Cell chemistry Li-ion Nominal voltage DC 14.4V Capacity 27.2Ah (390Wh) Charge voltage 16.8V Charge current Max. 6A Min. discharge power 26A ( 312W) D-Tap Output nominal voltage : 14.4V Min. Discharge power :12A (144W) USB Output voltage : DC 5.0V Max. load : 2.3A Auto power off : 30 minutes after no use End voltage 12V Battery protection circuit Over-charge, Over-discharge, Over-current ( Cell and Pack separately), Over-temperature, Reverse charge Ambient temperature To charge : 10°C ~ 30°C (32°F ~ 104°F recommended) To discharge : -20°C ~ 50°C ( -4°F ~ 122°F), 10°C ~ 40°C (50°F ~104°F recommended) To store : `-20°C ~ 40°C (-4°F ~ 104°F) (<85% RH) (less than 1 month) Dimension 97(W) x 146(H) x 97(D)mm 3.82(W) x 5.75(H) x3.82(D)" Weight approx. 2,000g / 4.4lbs EAN kode: 7311920026654 Type: Batterier

DKK 4499.00
1

GEN ENERGY Batteri G-B100/195W 195Wh/ 13.5Ah 15A Batteri

GEN ENERGY Batteri G-B100/195W 195Wh/ 13.5Ah 15A Batteri

G-B100/195W 15A V-MOUNT BATTERY Biggest power min. 180W can be supplied. ( 15A x 12V = 180W) It is the max. power through current standard v mount pin on the market. Min. 180W will give you relief on your mind when you use various equipment during shooting. D-tap has the biggest power also, 12A 144W. These days multi D-tap is getting more and more popular, so this 144W D-tap will be enough. - Shock-proof, Short-proof, Lowest impedance. CHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Charge the battery to full before first use. When you charge this battery, Battery capacity LED gauge button will turn on indicating the capacity being charged. Lithium ion batteries have a slight self discharge, therefore it is recommended to charge prior to use. DISCHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Camera's low voltage alarm is recommended to set 13~13.5V Battery will stop at 12V to extend its life.* Microwave transmitters with 5W outputs or over should be kept as far away from the battery. It may disrupt or stop supplying power. Be sure to remove the battery from the device after use. If so, it will consume large standby power and over-discharge protection may be activated. USB is activated by pushing Battery capacity LED gauge button. USB power will turn on automatically 30 minute after no use. Battery run time reduces when it is working below or above the recommended temperature range. SPECIFICATION TYPE V-MOUNT BATTERY Cell chemistry Li-ion Norminal voltage DC 14.4V Capacity 13.5Ah Charge voltage 16.8V Charge current Max. 6A Max. discharge rate 15A D-Tap Output norminal voltage : 14.4V Max. load :12A USB Output voltage : DC 5.0V Max. load : 2.3A Auto power off : 30 minutes after no use End voltage 12V Battery protection circuit Over-charge, Over-discharge, Over-current ( Cell and Pack separately), Over-temperature, Reverse charge Ambient temperature To charge : 10°C ~ 30°C (32°F ~ 104°F recommended) To discharge : -20°C ~ 50°C ( -4°F ~ 122°F), 10°C ~ 40°C (50°F ~104°F recommended) To store : `-20°C ~ 40°C (-4°F ~ 104°F) (<85% RH) (less than 1 month) Dimension 97(W) x 146(H) x 59(D)mm 3.82(W) x 5.75(H) x2.32(D)" Weight approx. 1070g / 2.35lbs EAN kode: 7311920026548 Type: Batterier

DKK 2544.00
1

GEN ENERGY Batteri G-B100/290W 290Wh/ 20Ah 22A Batteri

GEN ENERGY Batteri G-B100/290W 290Wh/ 20Ah 22A Batteri

G-B100/290W 22A V-MOUNT BATTERY This battery has 22A 264W, the biggest power in the world, which was born for ALEXA LF and Skypanel S60 full power working solution. You can use only 1 pc of 14.4V battery for ALEXA LF and 2 pcs of batteries for Skypanel S60. G-P22ALF plate is need for ALEXA LF with this 1 battery. G-PB48 power bank is needed for Skypanel S60 with these 2 batteries. Shock-proof, Short-proof, Lowest impedance. CHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Charge the battery to full before first use. When you charge this battery, Battery capacity LED gauge button will turn on indicating the capacity being charged. Lithium ion batteries have a slight self discharge, therefore it is recommended to charge prior to use. DISCHARGE Do not use the battery (Main, D-Tap, USB) while charging. If so, it may cause a charging error or damage the charger. Camera's low voltage alarm is recommended to set 13~13.5V Battery will stop at 12V to extend its life.* Microwave transmitters with 5W outputs or over should be kept as far away from the battery. It may disrupt or stop supplying power. Be sure to remove the battery from the device after use. If so, it will consume large standby power and over-discharge protection may be activated. USB is activated by pushing Battery capacity LED gauge button. USB power will turn on automatically 30 minute after no use. Battery run time reduces when it is working below or above the recommended temperature range. SPECIFICATION TYPE V-MOUNT BATTERY Cell chemistry Li-ion Norminal voltage DC 14.4V Capacity 20Ah Charge voltage 16.8V Charge current Max. 6A Max. discharge rate 22A D-Tap Output norminal voltage : 14.4V Max. load :12A USB Output voltage : DC 5.0V Max. load : 2.3A Auto power off : 30 minutes after no use End voltage 12V Battery protection circuit Over-charge, Over-discharge, Over-current ( Cell and Pack separately), Over-temperature, Reverse charge Ambient temperature To charge : 10°C ~ 30°C (32°F ~ 104°F recommended) To discharge : -20°C ~ 50°C ( -4°F ~ 122°F), 10°C ~ 40°C (50°F ~104°F recommended) To store : `-20°C ~ 40°C (-4°F ~ 104°F) (<85% RH) (less than 1 month) Dimension 97(W) x 146(H) x 78(D)mm 3.82(W) x 5.75(H) x3.07(D)" Weight approx. 1520g / 3.35lbs EAN kode: 7311920026562 Type: Batterier

DKK 4032.00
1